Solution Color Measurement Instrument

The solution colorimeter illuminates the sample solution with a light source and measures the relationship between the intensity of transmitted light and wavelength to obtain color data of the solution. It is used to detect the color, concentration, and purity of liquids, and is applied in industries such as chemical engineering, food, and environmental protection to monitor product quality and production processes.
Selection
When selecting, consider that the measurement wavelength range should cover the characteristic bands of the sample, the accuracy should meet detection standards, and it should be equipped with suitable cuvette specifications. Pay attention to the stability and repeatability of the instrument, the simplicity of the operation interface, and the functionality of the supporting software to match data processing needs. Choose the appropriate optical path structure and detector type based on the nature of the sample.

Terms

Standards

Instruments

Calcium Ion concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

Equipped with 18 standard color scale solution, prepared according to GB/T1722-92 standard, using an inner diaMeter of 10.75mm Glass testtube, Color comparison is carried out in the Color Assessment Cabinet to ensure accurate measurement results.

$ 136.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Glass shell with high strength can withstand temperature up to 80 ℃, can be filled with internal reference solution to prolong service life, and is suitable for the measurement of complex samples such as colloids.

$ 428.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily ion calibrating.

$ 135.00

Equipped with eight Illuminants and three measurement diaMeters, the repeability accuracy reaches 0.05, supports a variety of Color difference formulas and display modes, built-in whiteboard automatic correction, suitable for irregular surface and small area measurement.

$ 1687.00

Equipped with 50mm large measurement diameter, it can effectively deal with the Color measurement of uneven samples such as powder. Illuminant life of the instrument is up to 2 million times, the test port adopts full sealing design to prevent dust intrusion, and the Data storage capacity is up to 10,000 pieces.

$ 1187.00

500mL volume reduction pretreatment solution, using Reagent grade chemicals and tamper-proof sealing design to ensure solution freshness, support ElectRode Fast Response, suitable for ORP measurement reduction reaction conditioning.

$ 141.00

Equipped with eight Illuminant and eight Color difference formula, repeability accuracy of 0.05, support three display modes and 8mm general measurement aperture, built-in whiteboard automatic correction, suitable for a variety of materials Color measurement.

$ 1493.00

Concentration 1000ppm, Encasement with PTFE solution bottle, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy and Stability.

$ 135.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Cylindrical Mandrel Bending Tester for Detecting Flexibility of Coatings
This article introduces how the cylindrical shaft bending tester detects the flexibility of paints. Flexibility refers to the ability of the paint film to resist cracking when the substrate is bent.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.