Wood Drying Box

Wood drying kilns reduce the internal moisture content of wood through heating and ventilation systems to prevent deformation and mold, and are used for furniture manufacturing and pretreatment of building materials.
Selection
When selecting a wood drying oven, consider matching the capacity to the wood dimensions, ensuring temperature control accuracy meets material requirements, balancing energy consumption and cost, checking ventilation and safety design, and referring to user feedback.

Terms

Standards

Instruments

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Temperature uniformity is improved by fan speed control, the independent air duct circulation system automatically discharges water vapor, the dry culture mode is automatically converted, the temperature control accuracy fosters +/- 0.5 ℃, drying +/- 1 ℃, and the double door structure insulation does not affect the temperature in the box.

$ 722.00

Adopt needle measurement technology, support 150 kinds of wood measurement, measurement range 0~ 80%, accuracy +/- (0.5% n + 0.5), with LCD digital display and LED status indication, provide USB, RS-232 and Bluetooth data interface.

$ 222.00

Adopt mirror stainless steel argon arc welding box, Temperature range 10~ 200 ℃, Temperature Uniformity +/- 3%, equipped with microcomputer P.I.D temperature controller and hot air circulation system, can adjust the intake and exhaust volume.

$ 887.00

Measurement principle using resistance method, Measurement range 2~ 70%, accuracy +/- 2%, Response Time only 1 second. With 4 wood Measurement modes, support Data storage and voice reminder function.

$ 94.00

Using 3mm thick A3 steel plate and SUS201 stainless steel inner box, the size of each test box is 500 * 500 * 500mm, with pressure relief device and temperature and pressure control, effectively preventing battery explosion and ensuring safe operation.

$ 1535.00

With drying and foster dual mode automatic conversion function, Temperature Fluctuation foster +/- 0.5 ℃, drying +/- 1 ℃, using fan forced convection and autonomous air duct circulation system, improve Temperature uniformity and automatic discharge of water vapor.

$ 459.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Using electromagnetic wave scanning technology, measurement depth of 60mm, accuracy +/- 0.5%, Response Time of 1 second, no damage to the surface of the object, support 10 kinds of measurement code selection, automatic temperature compensation.

$ 169.00

The stainless steel inner box is used to ensure non-adsorption formaldehyde, the background concentration is as low as 0.006mg/m ³ and the holding time is long; Temperature range 15-40 ℃ accuracy +/- 0.5 ℃, humidity range 30-80% RH accuracy +/- 3%; low failure rate, the average initial maintenance interval exceeds 3 years.

$ 11321.00

Using 200g weight and 1cm ² bottom area design, in line with GB/T 1728 standard, through the filter paper test method to accurately determine the film surface drying and practical drying time, easy to operate, reliable results.

$ 114.00

Temperature resolution of 0.1 ℃, equipped with microcomputer P.I.D temperature controller and hot air circulation system, improve Temperature uniformity, support independent temperature limit alarm and intake and exhaust volume adjustment.

$ 393.00

Using 200 +/- 0.2 g weight and 1 square centiMeter bottom area design, the drying process of the paint film was accurately determined by the cotton ball method to distinguish between surface drying and actual stages in drying.

$ 115.00

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

Temperature range RT + 5~ 220 ℃, Temperature resolution 0.1 ℃, mirror stainless steel liner is easy to clean, forced warm air circulation ensures uniform temperature, and the box door automatically stops heating when opened.

$ 709.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Tensile testing machine for testing the bonding strength of wood plywood.
This article introduces the method for testing the bonding strength of wood plywood using a tensile testing machine. The test involves stretching plywood samples to measure the strength of the adhesive interface, in accordance with national standards such as GB/T 17657-2013.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.