Pressure Differential Moisture Meter

The differential pressure moisture analyzer heats the sample to generate water vapor, measures the change in gas pressure within a sealed system, and converts it into moisture content. It is used for rapid detection of moisture in solid or liquid materials and is suitable for quality control in industries such as chemical engineering and food.
Selection
When selecting a differential pressure moisture analyzer, it is essential to consider the compatibility of the sample characteristics with the heating temperature range, ensure that the measurement accuracy meets the process requirements, inspect the instrument's sealing performance and ease of operation, and choose an appropriate measurement chamber volume based on the typical sample quantity.

Terms

Standards

Instruments

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Moisture is measured by thermogravimetry, equipped with 500W high-efficiency halogen ring lamp for uniform heating, Temperature range 40-180 ℃ controllable. 5-inch Touchscreen real-time display of moisture change Linear dispersion, support automatic shutdown and Data storage 100 groups, intuitive operation without supervision.

$ 420.00

Suitable for Coulometry moisture determination, containing 500mL KF-1A Reagent and 5 bottles of 5mL KF-1B Reagent, supporting a variety of Moisture Meters to meet the needs of laboratory moisture analysis.

$ 236.00

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

Measurement range 0~ 1000ml/min, test area pressure accuracy of +/- 0.01kPa, equipped with 10cm ² standard test area and 35.68mm clamping ring, support different duration test.

$ 1098.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.