Fully automatic test with microcomputer control, pressure range 0~ -90kPa accuracy +/- 0.1kPa, equipped with 15mm thick Organic Glass sealing barrel and precision pneumatic components, support automatic constant pressure air replenishment and multi-point pressure calibrating.
High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.
Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.
Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.
The line pressure range is 0.33~ 80N/mm, and the width of the pressing roller is 300mm, which can complete ordinary pressing, high-pressure pressing, smooth pressing and calendering experiments, and support a variety of blanket pressing tests.
The pressure-sensitive element is used for automatic counting, the diaMeter of the culture dish supports ≤ Φ 90 mm, and it is equipped with dark deep background and annular fluorescent side-shot lighting. The colony contrast is clear, and the counting is fast and reliable.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.
Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.
Automatic counting using pressure sensitive elements, equipped with special probe pen and dark background lighting, culture dish diaMeter support ≤ Φ 90mm, fast and reliable counting and clear colony contrast.
With automatic temperature compensation and air pressure compensation function, Measurement range 0.00-20 mg/L, accuracy +/- 0.30mg/L, support Data storage 450 group and Bluetooth printing, dustproof and waterproof grade IP54.
The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.
Using high elasticity standard rubber and denim for extrusion test, extrusion pressure 10-120kgf adjustable, Test speed 5-30 times/minute, to meet the requirements of YD/1539-2006 standard.
Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.
The bar pressure can be adjusted freely, equipped with two or more fixed blocks and baffles of 500g/250g/100g weight, which supports accurate Spreader operation and improves experimental repeability and accuracy.
Touchscreen control, automatic constant pressure gas to ensure that the experiment in the preset vacuum, Vacuum Level range of 0~ -90KPa, a key operation automatically end the test, stable and durable performance.