Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure Spreader uniformity and test accuracy.
Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure accurate and reliable test results.
Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.
Using film lamination technology, with 0.29mm paper Film thickness and surface Laminating, providing uniform film Spreader and solvent chemical resistance, easy hiding power, Opacity test.
Using film lamination technology, it has excellent solvent and chemical resistance, ensuring uniform film Spreader, paper Film thickness 0.29mm, surface Laminating enhanced durability, suitable for a variety of test environments.
Using film lamination treatment, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and surface Laminating to ensure Spreader uniformity and test accuracy.
The calibrated value is 470mV, the capacity is 500mL, and the tamper-proof sealing design is adopted to ensure that the standard liquid has a valid period of up to 5 years in the unopened state to ensure the accuracy of calibrating.
Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent, ensure Spreader uniformity and with annotation section for easy recording.
Four-blade structure design, blade width 70mm, Rod length 300mm, low-speed operation to pRoduce tangential flow, the edge of the formation of high shear rate, effectively prevent media deposition, suitable for high viscosity fluid mixing.
The minimum detection limit of the adapter is 1cP, the operation temperature range is -40 ° C to 250 ° C, the stainless steel material is easy to clean, and the sample dosage is only 18-20mL, which is suitable for low viscosity fluid analysis.
Adopting the principle of rolling timing of the ball by inclined columnar measurement tube, the viscosity range 0.5-1000 00mPa · s, Temperature range -20 ℃ to 120 ℃, Repeatability is better than 0.5%, and the sample sealing measurement has no external interference.
Using 304 wear-resistant stainless steel material, application width 300mm, wet film thickness 18.3μm, suitable for uniform Spreader experiment of various fluid samples.
Using 304 wear-resistant stainless steel material, wet film thickness 18.3μm, Spreader width 300mm, suitable for a variety of fluid samples of experimental film requirements.
Measurement range covers 400~ 1800cst, round head Cup structure ensures fast inspection of various fluid viscosity, correction coefficient 0.95~ 1.05 to ensure data accuracy.
Using Dial display and manual Rotation speed control, Measurement accuracy of +/- 5%, viscosity range of 10 to 2000000mPa · s, support for a variety of rotor specifications and Rotation speed switching, suitable for a variety of fluid Tack test.