Using semiconductor refrigeration technology, temperature control accuracy of +/- 0.5 ℃, cooling time only 10 minutes from 25 ℃ to 4 ℃, with automatic fault detection and over-temperature protection function, support a variety of centrifuge tube module selection.
The ring method is adopted, the resolution reaches 0.1mN/m, supports automatic stop and average calculation, and is equipped with 24-bit AD converter and LVDT displacement Sensor to ensure Test accuracy and Repeatability.
Using platinum plate or ring method measurement, the range is 0~ 400mN/m, the minimum resolution is 0.1mN/m, the manual lifting and lowering points are fast and micro-adjusted, and the output data of RS232C interface is supported.
Measuring methods of platinum plate and platinum ring are supported, with resolution up to 0.01mN/m, equipped with fast fine-tuning manual lifting platform, and can display data in real time through RS232 interface.
Using platinum plate method measurement, accuracy of 0.1mN/m, equipped with 7-inch Touchscreen and electronic level, support automatic lifting and data management, to ensure stable and reliable measurement.
Portable design volume 145 * 52 * 23mm, support 100 sets of data storage and automatic calculation, with upper and lower limit alarm and USB communication functions, relative Indication Error only 0.5%, suitable for a variety of force value unit switching.
Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.
With 4.3-inch Touchscreen operation, the electromagnetic force equilibrating Sensor ensures high Sensitivity and 0.1mN/m accuracy, supports platinum plate method and ring method dual mode, fully automatic measurement direct display results, in line with many international standards.
Using BNC interface design, equipped with 60mL reference filling solution and calibrated solution, Measurement range, Response fast and stable, suitable for a variety of water quality environment testing needs.
High Accuracy measurement with 0.5% Relative Indication Error and 0.005N Graduation, supports gravity acceleration setting, upper and lower limit alarm, data storage analysis and USB communication functions to meet a variety of industrial testing needs.
Laser Sensor is used to directly measure the natural vibration frequency of the belt. The size of the split probe is only 124 * 21 * 12mm, which can penetrate into the depth of 66mm. Measurement range is 10-500Hz, and it supports metric and imperial unit switching.
Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Adopt automatic lifting system, the lifting speed can be adjusted from 0 to 300mm/min, equipped with electronic level to ensure Measurement accuracy, built-in measurement program to eliminate human interference, support dynamic smooth operation to reduce vibration impact.
Measurement range 0-200mN/m, accuracy +/- 0.02mN/m, support Automatic calibration and temperature compensation, real-time display test Linear dispersion and export Excel data.
Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.