Whiteness ColoriMeter

The whiteness and color measurement instrument measures the whiteness and color values of an object's surface by reflecting light. It uses a standard light source to illuminate the sample, and the sensor receives the reflected light and converts it into numerical values. It is used for whiteness detection and quality control of materials such as paper, coatings, and plastics.
Selection
When selecting, consider matching the measurement aperture to the sample size, support industry-standard whiteness formulas, ensure the instrument's repeatability error is less than 0.5, and include temperature compensation functionality. Verify the validity of the calibration certificate, and ensure the operation interface aligns with daily testing habits.

Terms

Standards

Instruments

Fully automatic one-click measurement of a variety of whiteness paraMeters, support chromaticity coordinates ≤ 0.001 High Accuracy, built-in thermal printer and RS232 interface, suitable for powder, paper and other samples.

$ 1818.00

Can measure ISO blue light whiteness and fluorescence whiteness, support powder whiteness measurement, Repeatability ≤ 0.02, built-in thermal printer, data can be cached and power-off protection, equipped with RS232 interface for easy communication.

$ 1051.00

Can measure ISO whiteness and fluorescence whiteness, Repeatability ≤ 0.02, support data cache and power-off protection, equipped with RS232 interface for easy communication, suitable for powder and flake samples.

$ 953.00

Using R457 whiteness formula, blue light whiteness and fluorescence whiteness can be measured simultaneously, Repeatability ≤ 0.3, Operating temperature 5~ 35 ℃, optical path design is simple to ensure measurement accuracy and Repeatability.

$ 432.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

Can measure ISO whiteness and fluorescence whiteness, equipped with diffuse ball diaMeter 150mm, test hole 19mm, support light scattering coefficient, absorption coefficient and other Optical inspection paraMeters, suitable for a variety of material surface whiteness analysis.

$ 1174.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Adopt 32-bit ARM processor to improve data processing speed, equipped with 5-inch true color Touchscreen to simplify the operation process, support one-click whiteness and chroma testing, Repeatability color coordinates ≤ 0.0003.

$ 3026.00

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

Using blue light whiteness R457 standard, Measurement range 0~ 100, Repeatability ≤ 0.5, Basis Weight can reflect fluorescent whitening effect and accurate measurement paper Opacity.

$ 654.00

It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.

$ 1348.00

R457 blue light whiteness measurement, Indication Error +/- 2.5, repeatability error ≤ 0.3, equipped with 10V/30W halogen tungsten lamp light source to ensure stable reflection performance detection.

$ 687.00

Geometry conditions were observed using d/o illumination, and the diaMeter of the diffuse sphere was 150mm, which can measure the diffuse reflection factor of blue light and the fluorescence whiteness, and support Multi-ParaMeter analysis such as Opacity and light scattering coefficient.

$ 1300.00

R457 blue light whiteness formula, Measurement range 0~ 100%, resolution 0.1, Repeatability ≤ 0.3, suitable for fluorescent whitening objects and paper Opacity measurement.

$ 490.00

Using LED Illuminant, 45/0 illumination conditions, Measurement range 0~ 199.9, Repeatability ≤ 0.3, suitable for whiteness measurement of white objects or powders, easy to carry and on-site detection.

$ 393.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Standardized ink color evaluation environment for visual color comparison cabinets
This article introduces the standardized application of visual color comparison boxes in ink color evaluation. It emphasizes that to ensure the accuracy and consistency of color judgments, the evaluation environment must be strictly controlled.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Principle and Application of Whiteness Meter in Measuring Coating Whiteness
A whiteness meter quantifies the whiteness of paint samples by simulating human perception of white, measuring the diffuse reflectance of light—particularly in the blue wavelength range—and converting it into a numerical whiteness value. It employs standardized optical configurations and mathematical models, such as the Ganz formula, to assess the brightness and chromaticity of coatings.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
The role of spectrophotometers in ink color matching
The spectrophotometer objectively quantifies color by measuring the spectral data of ink. Based on the Lambert-Beer law, it converts color into calculable spectral values, replacing traditional methods that rely on the human eye and experience.
Determination of Chromaticity Value of Pulp by Spectrophotometry
This article introduces the method for determining pulp chromaticity using spectrophotometry. It first explains the importance of chromaticity for pulp quality, then details the basic principles of spectrophotometry, which quantifies color by measuring the reflection of light from the pulp, typically expressed using the CIELAB color system.
Calibration and Use of Paper Whiteness Tester
This article introduces the working principle, calibration process, operational steps, and factors influencing the measurement results of a paper whiteness tester. The instrument evaluates whiteness by measuring the reflectance of blue light from paper, and calibration requires the use of a standard whiteboard in accordance with relevant standards.