Copper Plate Plating Thickness Gauge

The copper plate coating thickness gauge works on the principle of magnetic induction or eddy current. The probe contacts the coating, generating changes in the electromagnetic field to calculate the thickness. It is used to measure the thickness of metal coatings such as zinc or chromium on copper plates, ensuring coating uniformity. It is commonly used in electroplating workshops for quality control and incoming material inspection.
Selection
When selecting, consider matching the substrate type with the measurement principle: the magnetic induction method is suitable for steel substrates, while the eddy current method is suitable for non-ferrous metals. Choose the probe based on the coating material and thickness range; use a larger probe for rough surfaces. Check the instrument's calibration certificate and error range, and opt for a waterproof model in environments with high humidity.

Terms

Standards

Instruments

Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.

$ 509.00

Using copper nickel plating material, volume 37ml, in line with GB/T6750 standard, equilibrium hammer is hollow structure and filled with lead particles to adjust the weight, suitable for Coating and auxiliary materials, oil and other liquids specific gravity determination.

$ 106.00

Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.

$ 110.00

Measurement range 0.65-400 mm, the highest accuracy is +/- 0.04mm, supports four measurement modes, Data storage 3000 groups, high-speed measurement up to 10 times/second, suitable for a variety of metal materials.

$ 835.00

Lame plating movement rate 1-300mm/s, accuracy +/- 1%, support maximum 600 * 300mm substrate, can spray thickness 0.01~ 13mm, with 1L stainless steel pressure bucket, 5 inch touch screen control, energy consumption is only 100W.

$ 3623.00

Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.

$ 215.00

Using reciprocating lame plating technology, the effective lame plating area of 160 × 80mm can be expanded to 200 × 100mm. Support 0.1-5 ml/min precision discharge control, with Vacuum chuck platform to ensure the substrate is flat. Integrated PLC and Touchscreen realize paraMeter preset and real-time monitoring.

$ 4108.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

The formed pRoduction process ensures stable structure, wet film thickness can be controlled to 100μm, chrome plating surface preparation improves Abrasion Resistance and ease of cleaning, and the effective application width reaches 500mm.

$ 231.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

The wet film thickness can be as low as 1.5 μm, the groove bottom is wider to provide greater Coating Weight, the chrome plating surface and extrusion process ensure durability and easy cleaning, avoiding the problem of traditional steel wire loosening.

$ 477.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.

$ 141.00

Measurement range with 0.01mm high resolution and 0.65-400 mm width supports Probe automatic identification and multiple Measurement modes, which can penetrate the thickness of the coating measurement substrate and realize the data freezing display.

$ 1610.00

Articles

The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.
Application of Tensile Testing Machine in Coating Peel Strength Testing of Silicon-Carbon Anode Materials
This article introduces how to use a tensile testing machine to measure the bonding strength between silicon-carbon anode material coatings and copper foil substrates in lithium-ion battery research and development. During the test, the coating is peeled off using the 180-degree peel method at a constant speed, and the force variations throughout the peeling process are recorded.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.