Micro desktop centrifuge.

The micro benchtop centrifuge generates centrifugal force by driving the rotor to rotate at high speed via an electric motor, enabling the separation and sedimentation of components with different densities in samples. It is used for the rapid separation, concentration, or purification of small-volume samples in the laboratory, commonly applied in sample pre-processing in fields such as biochemistry and molecular biology.
Selection
When selecting, it is essential to match the common sample tube capacity, ensure the speed range covers experimental needs, and consider the temperature control function. Pay attention to the corrosion resistance of the rotor material, noise and vibration control during operation, and the simplicity of the user interface. Verify that the device dimensions are compatible with the workspace, and consider maintenance costs and the availability of accessories.

Terms

Standards

Instruments

The 6-well design supports 15ml capacity Sample Handling, which is suitable for a variety of Centrifuge models and provides stable centrifugal separation results.

$ 127.00

It is designed with 24-hole 0.5ml specification, suitable for a variety of Centrifuge models, with high temperature resistance and high voltage characteristics and excellent chemical Stability.

$ 127.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

The 12-well design has a capacity of 5ml per well, uses high transparency material for easy observation of samples, has excellent chemical Stability, and is suitable for mainstream Centrifuge models to improve experimental efficiency.

$ 127.00

Double-sided horizontal mounting design can accommodate 40 5ml centrifuge tubes, suitable for standard centrifuge tube specifications, improving Sample Handling efficiency and ease of operation.

$ 149.00

44 1.5ml or 2.0ml centrifuge tubes can be installed vertically on both sides, providing efficient Sample Handling capability, adapting to a variety of centrifuge tube specifications, and improving the convenience of experimental operation and space utilization.

$ 149.00

Support 100 ℃ thermostatic treatment, compatible with 35 1.5ml centrifuge tubes, optional 4-degree electronic ice box and intelligent thermostatic module, suitable for a variety of experimental scenarios.

$ 148.00

12 10ml or 15ml centrifuge tubes can be installed vertically on both sides, providing stable fixation and efficient mixing. They are suitable for a variety of centrifuge tube specifications and enhance the convenience of experimental operation.

$ 149.00

Support high temperature treatment at 100 ° C, adapt to 20 0.5ml and 15 1.5ml centrifuge tubes, and use thermostatic metal Bath design to ensure uniform and stable temperature and improve experimental efficiency.

$ 148.00

The 54-hole design is suitable for 0.5ml centrifuge tube, with a maximum temperature tolerance of 100 ° C. A variety of thermostatic modules can be selected to achieve accurate temperature control to meet various experimental needs.

$ 148.00

Standard HX-D module, support 35 2.0ml centrifuge tubes, withstand 100 ℃ high temperature, adapt to a variety of modules to meet the needs of multi-sample thermostatic treatment.

$ 148.00

High temperature resistance of 100 ° C, suitable for 32-hole 0.2ml, 10-hole 0.5ml and 15-hole 1.5ml centrifuge tubes, optional electronic ice box or thermostatic metal Bath module for enhanced temperature control flexibility.

$ 148.00

12 50ml centrifuge tubes can be installed vertically on both sides, and the vertical installation design is adopted for efficient Sample Handling. The capacity is suitable for standard 50ml tubes.

$ 149.00

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

The double-sided horizontal mounting design can simultaneously accommodate 16 50ml centrifuge tubes, which are suitable for standard 50ml tube specifications and provide a stable and reliable sample carrying platform.

$ 149.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.