ElectRode Coater

The electrode film applicator forms a uniform wet film on the substrate surface through mechanical blade coating, which is used for film thickness preparation and quality control of samples such as coatings and inks, facilitating subsequent performance testing.

Instruments

The Spin Coater is controlled by touch screen, the acceleration range is 100~ 4000rpm/s, and the speed can be automatically corrected by A/K selection. The motor torque is large and the operation is smooth, which is suitable for the assembly line process.

$ 2494.00

Designed for Calcium Composite ElectRode, 250ml Standard Encasement is provided to ensure ElectRode calibrating accuracy and long-term Stability for a variety of analytical scenarios.

$ 110.00

A calibrated solution specially designed for Iodine Ion Composite ElectRode, 250ml standard Encasement, provides a stable and reliable calibrated benchmark to ensure ElectRode Measurement accuracy and Repeatability.

$ 110.00

A calibrated solution specially designed for bromine ion composite ElectRode, with a capacity of 250ml, to ensure measurement accuracy and ElectRode performance stability, suitable for a variety of detection scenarios.

$ 110.00

The composite ElectRode design does not require reference ElectRode, the Solid State Sensor can be directly immersed in liquid measurement, the measurement range is 0.04 to 39000ppm, and the epoxy resin shell is durable.

$ 396.00

Designed for Fluoride Ion Composite ElectRode, 250ml standard Encasement is provided to ensure stable ElectRode performance and reliable measurement data, suitable for a variety of ion analysis scenarios.

$ 110.00

Specially designed for nitrate ion composite ElectRode, 250ml standard solution is provided to ensure stable ElectRode performance, simple and fast calibrating process, and improve Measurement accuracy and Reliability.

$ 110.00

Reagent grade chemicals can minimize the growth of ElectRode bacteria and keep the Glass film moist, 500mL capacity unopened valid period of up to 5 years, suitable for ElectRode cleaning and then hydration.

$ 127.00

Designed for Fluorine Boricacid ElectRode, it provides accurate calibrating support to ensure measurement Stability, 250ml Encasement is convenient for daily use in the laboratory, and improves detection efficiency.

$ 110.00

Designed for Perchlorate ElectRode, 250mL Standard Encasement is provided to ensure that the calibrating process is simple and efficient, improving ElectRode Measurement accuracy and long-term Stability.

$ 110.00

Designed for Potassium Compound ElectRode, the 250ml Encasement meets multiple calibrating requirements, providing a stable calibrating benchmark to ensure ElectRode Measurement accuracy and Repeatability.

$ 110.00

ElectRode filling solution design, suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, to ensure long-term stable operation of ElectRode, improve measurement accuracy.

$ 135.00

ElectRode composite design without reference ElectRode, measurement range 0.002 to 69000ppm, circular Glass sensitive film accurate sensing Ion concentration, operation temperature range 5~ 80 ° C, anti-interference ions such as silver, lithium, potassium, titanium.

$ 396.00

Dedicated to lead ion composite ElectRode calibrated solution, 250ml standard Encasement, provides a stable lead Ion concentration reference, to ensure ElectRode Measurement accuracy and long-term Stability.

$ 110.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

Articles

Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
The role of the coating machine in the preparation of fuel cell membrane electrode assemblies
The film coating machine is a key equipment for preparing the membrane electrode, the core component of fuel cells. It evenly coats a catalyst-containing slurry onto a substrate using techniques such as blade coating, slot-die extrusion, or spraying, forming a catalytic layer ranging from a few micrometers to several tens of micrometers in thickness.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
Inventory of Laboratory Coating Instruments
Laboratory coating tools include gap coaters, wire rods, automatic coating machines, etc. What are the differences between them? This article will tell you!
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.