The outflow aperture is 4mm, the outflow time is 0~ 150s, and the measuring hole is equipped with a switch for easy operation to ensure the accuracy of measurement and meet the GB/T1723 standard.
7Mm diaMeter outflow hole design, made of stainless steel, can be adapted to DIN viscosity Cup to achieve different test requirements, in line with the approximate DIN53211 standard specification.
It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.
Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.
Adopt aluminum alloy Cup body and stainless steel nozzle structure, the outflow aperture is 2mm, the viscosity measurement range is 15~ 30cSt, which is suitable for low viscosity thin liquid test, and the outflow time is controlled at 25~ 150 seconds.
Using stainless steel material, diaMeter 3mm outflow hole design, can freely replace the filter, expand the viscosity Cup test range, suitable for different liquid viscosity measurement needs.
Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.
3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.
Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.
The bottom hole and tip design are adopted, and the outflow time is determined by observing the appearance of the tip, which realizes rapid viscosity measurement and is suitable for on-site testing needs.
Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.
The filter diaMeter of 1-8mm can be freely replaced, the Cup mouth annular groove is designed to store overflow liquid, titanium anodic oxidation aluminum Cup body with stainless steel filter positioner, the distance between the outflow hole and the liquid level should be greater than 100mm.
Copper Cup with bracket structure, capacity 100 +/- 1ml, flow hole diaMeter 4mm, applicable to the flow time of 150 seconds or less viscosity test, through the flow time conversion kinematic viscosity value.
In line with DIN 53211 standard, the outflow time is 25~ 150s, the viscosity range is 15~ 30cSt, and the aluminum alloy Cup body and stainless steel nozzle are used to quickly test low viscosity liquids.
6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.