Recirculating Constant Temperature Oil Bath

The circulating constant temperature oil bath heats up via a heater, drives the flow of heat transfer oil with a circulating pump, and maintains the set temperature in conjunction with a temperature controller. It is used for constant temperature heating of laboratory samples, temperature control in reaction vessels, and other scenarios to ensure uniform and stable temperature.
Selection
When selecting, consider that the temperature range should match experimental needs, the temperature control precision should be determined based on sample sensitivity, the tank capacity should accommodate container sizes, the circulation flow rate affects heat exchange efficiency, and attention should also be paid to material corrosion resistance and safety protection features.

Terms

Standards

Instruments

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Adopt microcomputer PID temperature controller, temperature control accuracy +/- 0.5 ℃, over-temperature sound and light tracking alarm to protect samples, stainless steel liner shell anti-corrosion and easy to clean, support internal and external circulation.

$ 680.00

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

Temperature control accuracy +/- 0.5 ℃, Temperature range 20~ 200 ℃, equipped with microcomputer PID controller and over-temperature sound and light alarm function to ensure sample safety, stainless steel liner easy to clean and corrosion resistance.

$ 798.00

Using DC motor to ensure no-load operation for more than 10,000 hours, no noise vibration; fast IT microcontroller to achieve accurate adjustment of speed and temperature, support dry burning, water Bath and oil Bath various working modes, Temperature range RT +~ 300 ℃, heating power 800W.

$ 172.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 1 ℃, equipped with imported pumps to ensure uniform temperature, strong corrosion resistance, compact structure, long service life.

$ 522.00

Temperature control accuracy of +/- 1 ℃, Temperature range RT +~ 299 ℃, stainless steel studio water Tank, excellent corrosion resistance, digital display automatic temperature control, easy and reliable operation.

$ 414.00

Temperature range RT +~ 300 ℃, Tank volume 3L, stainless steel material high temperature corrosion resistance, intelligent integrated circuit to achieve accurate temperature control, LED display intuitive and clear.

$ 190.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.