Small Temperature Test Chamber

The small temperature test chamber controls the internal temperature through a heating and cooling system to simulate different environmental conditions. It is used to test the performance changes of materials under temperature variations and is commonly employed in quality inspections of electronic components and chemical products.
Selection
When selecting, consider that the temperature range should cover testing requirements, the heating and cooling rates should match experimental standards, the chamber dimensions should accommodate the sample volume, the control accuracy should meet inspection requirements, and the stability should satisfy long-term operation.

Standards

Instruments

The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.

$ 2300.00

The equilibrated refrigeration technology makes the temperature fluctuation small, and the fluorine-free R134 refrigerant is more energy-saving and environmentally friendly. Temperature range 0~ 60 ℃, Humidity Control Range 50~ 90%, intelligent humidification system and mirror stainless steel liner.

$ 1602.00

Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.

$ 444.00

The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.

$ 5023.00

With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.

$ 4438.00

Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.

$ 5023.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.

$ 1203.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

The equilibrate refrigeration technology makes the temperature fluctuation small, equipped with fluorine-free R134 refrigerant to achieve energy saving and environmental protection, temperature control accuracy of +/- 0.1 ℃, reasonable air duct circulation system to ensure uniform temperature in the studio.

$ 1979.00

Rotation speed stable and no temperature rise, Max. stirring Capacity 3L, Speed range 0~ 1500rpm, suitable for small capacity single stirring needs.

$ 148.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00