Temperature Fluctuation control at +/- 0.05 ℃, Display resolution up to 0.1 ℃, equipped with circulating pump Flow rate 8L/min, support computer two-way communication and liquid level alarm to ensure stable and reliable experiment.
Temperature control accuracy of +/- 0.05 ℃, resolution 0.1 ℃, equipped with 10L/min circulating pump and Pt100 temperature sensor, support computer communication and liquid level alarm function.
Single chip microprocessor control and self-tuning PID adjustment, temperature control accuracy of +/- 0.05 ℃, Temperature Fluctuation is small; equipped with 10L/min circulating pump to ensure uniform temperature in the Tank, fully enclosed Compressor refrigeration system stable and reliable operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, integrated PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with multiple Safety protection devices.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ° C. Integrated PID automatic temperature control program and High Accuracy PT100 Sensor ensure stability and accuracy.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, temperature control accuracy +/- 0.5 ℃, with low water level protection, temperature runaway alarm and other multiple safety functions to ensure the stable operation of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with PID automatic temperature control program, with low water level protection, temperature runaway protection and other multiple safety functions.
Temperature control accuracy of +/- 0.05 ℃, the use of non-heat centrifugal circulating pump and U-shaped return design, to achieve a high degree of uniform temperature field, effectively reduce temperature field interference, to ensure stable and reliable operation.
Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.
Temperature range -65~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity in the Tank.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display and PID automatic temperature control to ensure stable and safe operation.
Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity +/- 0.05 ℃, equipped with multi-level Safety protection device, optional program temperature control and Communication interface, to achieve accurate and stable temperature control.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Fluctuation +/- 0.05 ℃, temperature control accuracy +/- 0.5 ℃, with multiple safety devices such as low water level protection and temperature runaway protection.