Using platinum plate method measurement, accuracy of 0.1mN/m, equipped with 7-inch Touchscreen and electronic level, support automatic lifting and data management, to ensure stable and reliable measurement.
Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
Portable design volume 145 * 52 * 23mm, support 100 sets of data storage and automatic calculation, with upper and lower limit alarm and USB communication functions, relative Indication Error only 0.5%, suitable for a variety of force value unit switching.
The ring method is adopted, the resolution reaches 0.1mN/m, supports automatic stop and average calculation, and is equipped with 24-bit AD converter and LVDT displacement Sensor to ensure Test accuracy and Repeatability.
Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.
With 4.3-inch Touchscreen operation, the electromagnetic force equilibrating Sensor ensures high Sensitivity and 0.1mN/m accuracy, supports platinum plate method and ring method dual mode, fully automatic measurement direct display results, in line with many international standards.
It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.
High Accuracy measurement with 0.5% Relative Indication Error and 0.005N Graduation, supports gravity acceleration setting, upper and lower limit alarm, data storage analysis and USB communication functions to meet a variety of industrial testing needs.
250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
Laser Sensor is used to directly measure the natural vibration frequency of the belt. The size of the split probe is only 124 * 21 * 12mm, which can penetrate into the depth of 66mm. Measurement range is 10-500Hz, and it supports metric and imperial unit switching.
Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.
Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Adopt automatic lifting system, the lifting speed can be adjusted from 0 to 300mm/min, equipped with electronic level to ensure Measurement accuracy, built-in measurement program to eliminate human interference, support dynamic smooth operation to reduce vibration impact.
Measurement range 0-200mN/m, accuracy +/- 0.02mN/m, support Automatic calibration and temperature compensation, real-time display test Linear dispersion and export Excel data.