Adjustable Micro Pipette

The adjustable micropipette quantitatively draws liquid through piston movement, with the adjustment knob used to set the volume. It is used for accurately transferring microvolumes of liquid in the laboratory, suitable for operations such as sample preparation and reagent addition.
Selection
When selecting, consider matching the measurement range with experimental requirements, check for precision errors, and confirm material corrosion resistance. Ensure the device is lightweight and easy to handle, with replaceable maintenance components, and compatible with commonly used pipette tip specifications.

Terms

Standards

Instruments

Continuous adjustable micro sampling, range 2-20ul, accuracy error +/- 0.90%, nozzle ejector removable for high temperature and high voltage disinfection and cleaning maintenance.

$ 89.00

Continuous adjustable micro sampling, range 0.1~ 2.5μL, accuracy error +/- 2.50%, nozzle ejector removable for high temperature and high voltage disinfection and cleaning maintenance.

$ 88.00

Continuously adjustable micro-pipetting, range 10-100ul, accuracy error +/- 0.80%, nozzle ejector removable for high temperature and high voltage disinfection cleaning and maintenance.

$ 89.00

Range 1-10ml, accuracy error +/- 0.60%, nozzle ejector removable and high temperature and high voltage sterilization, easy to clean and maintain, with lightweight design and clear reading window.

$ 89.00

Capacity 1000ul, Minimum Encasement 500 pcs/pack, Sterile design to ensure experimental accuracy, suitable for a variety of Pipette use.

$ 77.00

The 15-hole design is suitable for 10ml suction heads, which are specially matched for HYD-1WB Pipette to ensure accurate and stable pipetting process and improve experimental operation efficiency.

$ 79.00

The 10ul capacity specification is used with the standard Pipette, and each pack of 1000 packs meets the needs of batch experiments. The transparent material is convenient for observing the liquid level.

$ 77.00

Capacity 10ml, minimum Encasement 100 pcs/pack, sterile independent Encasement to ensure experimental cleanliness, conical design to ensure airtightness, suitable for a variety of brands Pipette use.

$ 89.00

The 96-hole design is suitable for a variety of Pipette models, and the 200ul capacity meets the needs of routine experiments to ensure that the suction heads are neatly stored and easy to use.

$ 76.00

The 96-hole design is adopted, with a capacity of 10ul, and it is suitable for HYD-0.1B/0.5B Pipette to ensure stable placement and quick access of the suction head, which improves the efficiency and accuracy of the experiment.

$ 76.00

Range 1-5ml, accuracy error +/- 0.50%, nozzle ejector removable and high temperature and high voltage disinfection, easy to clean and maintain, light operation.

$ 89.00

The range is 0.5~ 10 μL, the accuracy error is as low as +/- 1.00%, the nozzle ejector can be removed and supports high temperature and high voltage disinfection, which is easy to clean and maintain, and the operation is light and the reading is clear.

$ 89.00

The 60-hole design is suitable for 1ml suction heads, which are specially optimized for HYD-100B Pipette to ensure stable storage and quick access of the suction heads, and improve the experimental efficiency.

$ 76.00

The 28-hole design can accommodate 5ml suction heads and is suitable for HYD-1000B Pipette to ensure that the suction heads are stored in an orderly manner and easy to use, improving the experimental efficiency.

$ 79.00

Range 100-1000 μl, accuracy error +/- 0.60%, nozzle ejector removable and supports high temperature and high voltage disinfection, easy to clean and maintain.

$ 89.00

Articles

Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
The laboratory coating machine easily coats various aqueous and oily slurries.
The laboratory film applicator is a precision instrument used to prepare uniform coatings on substrates, primarily operating on the principle of a blade or wire-wound rod. It allows adjustment of parameters such as speed and pressure to control coating thickness.