Multi-functional Moisture Meter

The multi-functional moisture analyzer evaporates water from the sample by heating it and calculates the moisture content by measuring the weight loss. It is used for moisture detection in materials such as coatings and plastics to ensure stable production quality.
Selection
When selecting, consider matching the sample form with the heating method, ensuring the temperature range covers material properties, weighing accuracy meets testing requirements, the operation interface aligns with usage habits, and maintenance costs fit the budget.

Terms

Standards

Instruments

16Mm large diaMeter is suitable for striped fabric and leather measurement, Repeatability Delta E * ab < 0.05, with multi-functional test components can measure liquid, powder and other samples to improve measurement accuracy.

$ 1897.00

Temperature range RT + 5~ 60 ℃, Oscillation Frequency 0~ 320rpm, support rotary and reciprocating oscillation mode, liner made of stainless steel corrosion resistance, stepless speed control smooth operation.

$ 883.00

Maximum pull-out force 40kN, using three-point reaction support and post-loading pull-out method principle, with color Touchscreen display force value and time Linear dispersion, support automatic storage of 10000 data.

$ 837.00

With 0~ 300rpm stepless speed regulation and 20mm swing amplitude, the multi-functional spring bottle test rack supports a variety of comparison experiments, and the low center of gravity of the whole machine ensures stable and reliable continuous work.

$ 298.00

Equipped with multi-functional test components to measure liquid and powder samples, 8mm measurement caliber to ensure accurate positioning, Repeatability fluctuation is less than 0.07 on average, light positioning function simplifies the operation process.

$ 1655.00

With a multi-functional spring bottle test rack, it supports a variety of comparative experiments; the stepless speed range is 0~ 250rpm, and the pendulum amplitude is 25mm; the center of gravity of the whole machine is low, and the continuous work is stable and reliable.

$ 364.00

Temperature control accuracy of +/- 1 ℃, Oscillation Frequency start~ 300rpm, with oxygen holes to ensure full oxygen, equipped with multi-functional spring bottle rack for a variety of comparative experiments, stepless speed control smooth operation and safety.

$ 503.00

The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.

$ 1977.00

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

With needle and inductive two measurement modes, the measurement range is 0-80% and 0-70% respectively, accuracy +/- (0.5% n + 0.5), support USB, RS-232 and Bluetooth multiple data interfaces, equipped with color coded LED real-time display moisture status.

$ 275.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Measurement range 0-99.9%, Response Time 1 second, Multi-gear selection and 50mm scanning depth, suitable for on-site rapid moisture determination.

$ 223.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.