Electric Forced Air Constant Temperature Drying Oven

The electric hot air drying oven heats air through electric heating tubes, with a fan circulating the hot air inside the chamber, and a temperature controller maintains the set temperature. It is used for drying samples, removing moisture, and curing materials. It is applied in routine operations such as laboratory sample drying, material heat treatment, and industrial component drying.
Selection
When selecting, consider matching the chamber size to the sample volume, ensuring the temperature range covers the required usage, and the temperature control precision meets experimental needs. Pay attention to the balance between heating power and heating speed, as the type of fan affects temperature uniformity. The materials should be corrosion-resistant, and safety protection features must be comprehensive.

Terms

Standards

Instruments

Using forced warm air circulation to ensure uniform temperature, Temperature resolution of 0.1 ℃, equipped with microcomputer LCD controller temperature control is accurate, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 457.00

Temperature uniformity is ensured by forced circulation convection air duct, temperature control accuracy of 0.1 ℃, with Sensor fault alarm and over-temperature protection function, Timer Range can be selected from 0-9999 minutes or hours, suitable for a variety of non-flammable and explosive materials processing.

$ 659.00

Forced circulation convection air duct to ensure uniform temperature, Temperature range Rt + 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and up to 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.

$ 561.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.

$ 761.00

Mirror stainless steel liner is easy to clean, Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ or +/- 1 ℃, with forced warm air circulation and timing function to ensure uniform and stable temperature.

$ 470.00

Vertical double air duct vertical hot air circulation design to ensure Temperature uniformity +/- 1 ℃, turbine centrifugal fan blades with bust system, adjustable shelf spacing, equipped with double-decked tempered Glass observation window and high temperature sealing strip.

$ 1775.00

Fuzzy PID controller is used to ensure accurate temperature fluctuation, forced convection duct to raise Temperature uniformity to +/- 1.5 ℃, automatic control of circulating fan speed to avoid sample volatilization, mirror stainless steel liner and electric heating film Heating mode to achieve rapid and uniform heating.

$ 804.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 553.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, using mirror stainless steel liner and forced convection technology to ensure uniform temperature, four corners and a half arc easy to clean, the door opens automatically stop heating.

$ 1125.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Horizontal forced convection technology to ensure the studio Temperature uniformity, temperature control accuracy of 0.1 ℃ and Fluctuation +/- 1 ℃; Sensor fault alarm, over-temperature protection and 9999 minutes timing function, 304 stainless steel studio corrosion resistance easy to clean.

$ 367.00

With drying and foster dual mode automatic conversion function, Temperature Fluctuation foster +/- 0.5 ℃, drying +/- 1 ℃, using fan forced convection and autonomous air duct circulation system, improve Temperature uniformity and automatic discharge of water vapor.

$ 459.00

Adopt hot air circulation system to ensure Temperature Uniformity +/- 2 ℃, support 1-9999 minutes timing control, with RS-485 communication interface optional, suitable for drying and sterilizing operations.

$ 333.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Pendulum Impact Tester Evaluates Impact Strength of Glass Fiber Reinforced Nylon
This article introduces the use of a pendulum impact tester to evaluate the impact strength of glass fiber reinforced nylon. The test is based on the principle of energy conservation, where the energy absorbed by the material is calculated by measuring the height difference of the pendulum before and after impacting the specimen, thereby quantifying its impact resistance.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Peel strength tester measures the peel force of hot melt adhesive resin.
The peel strength tester is used to measure the adhesive properties of hot melt adhesive resins, simulating the actual peeling process by recording changes in force values through constant-speed stretching.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Method for Determining Peel Strength of Hot Melt Adhesives Using an Electronic Tensile Tester
This article introduces the standard method for determining the peel strength of hot melt adhesives using an electronic tensile testing machine. The test employs a 180° peel mode, where a sample coated with hot melt adhesive is clamped in the machine's fixtures and peeled at a constant speed. The peel strength is calculated based on the recorded force variations.