With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, resolution 0.1 ℃, pump flow rate 6L/min, to ensure temperature uniformity, support connection with external equipment.
Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.
With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.
Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.
Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.
It has the function of water shortage and air burning and independent temperature limiting system, temperature control accuracy +/- 0.3 ℃, adopts one-time stamping forming stainless steel liner, supports internal and external circulation and timing operation.
With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.
With dual functions of internal and external circulation, Temperature Fluctuation is only +/- 0.05 ℃, resolution is 0.01 ℃, pump flow rate is 6L/min, to ensure temperature uniformity and Stability, support external experimental equipment.
With dual functions of internal and external circulation, Temperature Fluctuation is only +/- 0.05 ℃, resolution is 0.01 ℃, pump flow rate is 6L/min, ensuring temperature uniformity and corrosion resistance.
With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, volume 20L, pump flow 6L/min, improve temperature uniformity and accuracy, suitable for connecting a variety of experimental equipment.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.
The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.
Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.
Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.