Dial Indicator Tension Meter

The pointer-type tension meter uses spring deformation to drive the pointer rotation, directly displaying the tension value. It is used to measure the tensile strength of materials and determine the breaking load in quality inspections of rubber and textiles.
Selection
When selecting, consider the maximum range to cover testing needs, ensure the dial scale is clear and easy to read, ensure the fixture matches the shape of the specimen, verify the calibration cycle complies with industry standards, and ensure the structure is sturdy to minimize vibration effects.

Terms

Standards

Instruments

Dial indicator reading is accurate, with dual unit display without conversion, maximum Measured value 100N, Indication Error +/- 1%, can freely switch peak holding and real-time load value, suitable for all kinds of fixture installation.

$ 136.00

Dial indicator reading accuracy, with peak holding and real-time load measurement switching function, the maximum Measured value 30kg, Indication Error +/- 1%, compact and portable and easy to operate.

$ 136.00

Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.

$ 825.00

With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.

$ 635.00

Dial indication for easy reading, with dual unit display function without conversion, can freely switch peak holding and real-time value mode, Measurement accuracy of +/- 1%, push-pull Rod Travel 10mm, suitable for all kinds of fixture installation.

$ 136.00

Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.

$ 457.00

Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.

$ 457.00

The handheld design is small in size, the pointer reading is convenient and accurate, the peak protection and continuous load are freely switched, the tolerance band indicator can set the upper and lower limits, the Newton kilogram dual unit display, the maximum Measured value is 300N, and the Indication Error is +/- 1% FS.

$ 175.00

Pointer indicator reading, accuracy of +/- 1% FS, with peak protection function and continuous load indication free switching, with tolerance band indicator for batch testing, support Newton and kilogram dual unit display.

$ 175.00

Equipped with peak protection and continuous load dual mode, tolerance band indicator can set upper and lower limits, Indication Error +/- 1% FS, handheld design with a variety of fixtures to achieve accurate push-pull load testing.

$ 175.00

The handheld design is compact, the pointer reading is convenient, the peak protection and continuous load switching, the tolerance band indicator can set the upper and lower limits, the accuracy is +/- 1% FS, and the Newton kilogram dual unit display.

$ 175.00

With peak protection and continuous load indication switching function, equipped with tolerance band indicator to set the upper and lower limits, accuracy of +/- 1% FS, while displaying Newton and kilogram units, handheld design for easy portability.

$ 175.00

Small portable size only 225mm * 60mm * 51mm, Dial reading accuracy +/- 1%, with peak holding and real-time load switching function, support dual unit display without conversion, push-pull Rod Travel 10mm.

$ 136.00

Dial display, viscosity measurement range of 10~ 100000mPa · s, accuracy +/- 5% F. S, equipped with four rotors and four Rotation speed, suitable for a variety of fluid viscosity detection, easy to operate.

$ 346.00

Measurement range 0-10mm, accuracy ≤ 0.02mm, using Dial reading, Graduation 0.01mm, upper probe diaMeter 6mm plane, suitable for workshop site and laboratory thickness measurement.

$ 219.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Determination of Static Surface Tension of Color Coatings Using the Platinum Plate Method with a Surface Tensiometer
This article introduces the method of measuring the static surface tension of colored paints using the platinum plate method. It explains the principle, which involves calculating the surface tension by measuring the force when the platinum plate is lifted from the liquid surface.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Electronic tensile testing machine testing the tensile strength of packaging film
This article introduces the method of testing the tensile strength of packaging films using an electronic tensile testing machine. It first explains the importance of tensile strength for packaging films, then details the testing principles, equipment composition, and the necessity of preparing samples according to standards.
Method for Determining Peel Strength of Hot Melt Adhesives Using an Electronic Tensile Tester
This article introduces the standard method for determining the peel strength of hot melt adhesives using an electronic tensile testing machine. The test employs a 180° peel mode, where a sample coated with hot melt adhesive is clamped in the machine's fixtures and peeled at a constant speed. The peel strength is calculated based on the recorded force variations.
Adhesion tester evaluates the bonding strength between coating and substrate.
The adhesion tester is a device used to measure the bonding strength between a coating and the substrate. It applies a pulling force until the coating detaches, records the force value, and calculates the strength. Common testing methods include the pull-off method, cross-cut method, etc., each with corresponding standards.
Pull-off testing for interlayer adhesion of multilayer coating systems.
This article introduces the pull-off method for testing the interlayer adhesion of multilayer coating systems. The test involves vertically bonding a pull-off head to the coating surface and applying a pulling force until the coating separates, measuring the required force to evaluate adhesion strength.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
Tensile testing machine for testing the puncture resistance of film materials.
This article introduces how to use a tensile testing machine to test the puncture resistance of film materials. Puncture resistance is a key indicator for measuring a film's ability to resist penetration by sharp objects, directly affecting the protective performance of packaging.