Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.
Adopt DC electromagnetic control to achieve accurate ball drop, infrared point positioning to ensure drop accuracy, height adjustable range 0-1500mm, support 55g to 535g steel ball weight, equipped with data recording system to monitor Impact paraMeters in real time.
DC electromagnetic control ball drop, equipped with infrared pointing system to ensure accurate drop position, height adjustment range 0-2000mm, support a variety of steel ball weight selection, to meet the material anti-Impact performance testing needs.
LED Infrared source and scattering - transmission light measurement principle, range 0.000-1000NTU, support multi-point calibrating and 2000 data storage, with automatic power-off and USB power supply function, in line with ISO7027 standard.
Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.
Adopt 860nm infrared LED Illuminant, in line with ISO7027 standard; Support scattering and scatter-transmission dual Measurement principle; With IP65 Protection Rating and automatic range switching function; Standard long-lasting turbidity calibrated set.
Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.
Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.
Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.
Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.
Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with stainless steel liner, rapid and uniform heating, suitable for drying a variety of samples.
Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.