The small-scale high-temperature Coater uses a heating system to bring the substrate surface to the set temperature and employs a blade or roller to apply the coating evenly onto the substrate. Its function is to simulate industrial coating processes in a laboratory environment, facilitating coating process testing and sample preparation for materials such as paints and adhesives. Applications include coating development and quality control for materials such as paper, films, and metal foils.
Selection
When selecting, consider the matching of the maximum temperature with the material's temperature resistance, ensuring the coating width covers the sample size and the coating speed meets experimental needs. The heating method affects temperature control accuracy and should be determined based on the material's thermal sensitivity. The coating thickness range should be suitable for the sample specifications, and the equipment dimensions must align with the laboratory space. The operating interface should be simple and user-friendly, with easy maintenance and cleaning.

Terms

Standards

Instruments

Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.

$ 444.00

The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.

$ 5023.00

Support 10-20mL small sample testing, viscosity range 80-40000000mPa · s, equipped with a dedicated rotor for High Accuracy measurement, Thermostatic Bath connection can control the sample temperature.

$ 1732.00

Measurement accuracy is increased by 96% with integrating sphere structure coating. Standard Deviation Delta E * ab ≤ 0.06 ensures Data Stability and supports a variety of chroma space and Illuminant selection.

$ 703.00

The equipment adopts High Accuracy modular Spreader station, Spreader thickness range 0.01mm~ 2mm, coating speed 2~ 4.5m/min adjustable, with UV instant curing and heating function, suitable for a variety of materials such as paper, film and so on.

$ 10562.00

Measurement range 0.0~ 500μm, error +/- (0.3μm + 2%), ultra-small probe suitable for nails, bolts and other small workpiece thin platings measurement, with multi-point calibrating and statistical functions to ensure high Repeatability and Stability.

$ 906.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises quickly, the maximum operating temperature is 380 ° C and supports continuous work, and the hemispherical design is not easy to bruise Glass ware.

$ 222.00

With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.

$ 4438.00

Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.

$ 954.00

Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.

$ 5023.00

Fast sterilizing in ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, the built-in over-temperature protection device, and the stainless steel liner container ensures safety and durability.

$ 396.00

Suitable for high temperature surface measurement, the highest temperature up to 250 ℃, Measurement range 0~ 1000 microns, accuracy +/- (2μm + 3%), equipped with high contrast ratio color LCD screen, Data storage 1000.

$ 1721.00

Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.

$ 1203.00

Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.

$ 178.00

Adopt 1.5 × 2 mm elliptical measurement window, suitable for small area measurement, Stability up to 0.4GU, Operating voltage only 1.5V a AA battery, portable and easy to use.

$ 533.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.