Doctor Blade Sheet Coater

The blade Coater controls the coating thickness through the gap between the blade and the substrate, with the blade scraping off excess coating to form a uniform layer. It is used for coating substrates such as paper and films to achieve surface modification and functional layer coverage.

Instruments

Using Metering Rod & doctor blade double Spreader mode, Spreader accuracy up to +/- 0.001mm, Spreader rate 5~ 200mm/s adjustable, fixed substrate by vacuum adsorption to ensure film uniformity and repRoducibility.

$ 2736.00

Spreader speed 5~ 180mm/s, Spreader area 400 * 300mm, using Metering Rod & doctor blade and vacuum adsorption system to ensure Spreader uniformity and Stability, can be customized automatic inking function.

$ 9755.00

Using Metering Rod & doctor blade dual Spreader method, Spreader accuracy is up to +/- 10μm, Film thickness range is 0-5000μm. Spreader rate and stroke are controlled by vacuum adsorption to fix the substrate, and the touch screen can effectively improve film repRoducibility and conformity.

$ 3462.00

The application width can be adjusted freely, and the drawdown blade Coater can be adapted to meet different experimental testing needs and realize flexible film operation.

$ 154.00

Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm, equipped with automatic feeding system and vacuum adsorption, to achieve stable Spreader and efficient operation.

$ 8949.00

Spreader speed 5-180mm/s adjustable, wire Rod Spreader accuracy +/- 0.001mm, using touch screen control and mechanical fixture to ensure stable and reliable Spreader process.

$ 2010.00

Adopt bar and drawdown blade composite coating method, bar accuracy +/- 0.005mm, drawdown blade thickness range 0.1-10 mm, Vacuum Area 1280 * 960mm, coating speed 1~ 300mm/s stepless speed regulation, suitable for wide voltage input.

$ 19438.00

Spreader speed 5~ 200mm/s continuously variable speed, scraper Spreader accuracy +/- 0.003mm, support heating temperature RT +~ 180 ℃, baseplate heating method to ensure stable Spreader effect, improve experimental conformity.

$ 7658.00

Adopting direct temperature control technology, the heat exchange speed is only 1-3 seconds, the speed range is 100-3000rpm, and it has 5 speed adjustment and 12 groups of parameter memory functions to improve the stability of the coating.

$ 5399.00

Spreader accuracy of +/- 0.001mm and +/- 0.003mm respectively, support 5~ 200mm/s stepless speed change and vacuum adsorption fixation, improve coating conformity.

$ 7141.00

The Spin Coater is controlled by touch screen, the acceleration range is 100~ 4000rpm/s, and the speed can be automatically corrected by A/K selection. The motor torque is large and the operation is smooth, which is suitable for the assembly line process.

$ 2494.00

Using meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, clamshell Drawdown blade is easy to clean, supports 1-300mm/s stepless speed regulation, Glass countertop heat resistance 600 ℃ and scratch resistance.

$ 9433.00

Utilizing a dual coating method with wire rod and doctor blade, the coating speed is adjustable from 1 to 300 mm/s with stepless speed control, ensuring high precision in film thickness control. Equipped with vacuum adsorption and heating functions, the temperature uniformity reaches ±1°C. The flip-top design facilitates easy cleaning.

$ 24279.00

Adopt bar and drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, effective coating area 1000 * 300mm, clamshell drawdown blade design is easy to clean, servo motor drive to ensure stable operation.

$ 7012.00

Adopt bar and Drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, bar accuracy +/- 0.001mm, equipped with clamshell Drawdown blade head for easy cleaning, Glass countertop heat resistance 600 ℃.

$ 5560.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
How to Coat High-Viscosity Slurry – Parameter Setting Tips for Blade Coaters
This article primarily discusses the parameter setting techniques for high-viscosity slurries on blade coaters. High-viscosity slurries exhibit characteristics such as shear thinning, so it is essential to leverage shear effects during coating to facilitate slurry spreading. After coating, the viscosity should recover quickly to prevent sagging.
What are some cost-effective alternatives to roll-to-roll coaters for the early stages of flexible film R&D when the investment is too high?
The investment in roll-to-roll coating machines is too high. What are some cost-effective alternatives for the early stages of flexible film research and development? Among blade coating, spin coating, and spray coating, which one would you choose?