Digestion water Bath

The digestion water bath uses electric heating to maintain a constant water temperature, allowing samples to be thermally decomposed in sealed or open containers. It is used for sample pretreatment in laboratories, such as dissolving solid samples for heavy metal detection in coatings.
Selection
When selecting, consider the compatibility of sample material and volume with capacity. Temperature control accuracy must meet testing standards, and heating uniformity affects result consistency. Corrosion-resistant materials should be used to adapt to acidic or alkaline environments. Operational safety features include dry-burning prevention and overheating protection.

Terms

Standards

Instruments

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.

$ 1355.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

The separate design of digestion and determination does not affect the accuracy, COD digestion is completed in 15 minutes, 30 standard Linear dispersion and 199 sets of data can be saved, 4-16 water sample batches are supported, and IP65 waterproof and dustproof design is adopted.

$ 1366.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Heat and corrosion resistant material, can digest 25 samples at the same time, Temperature Stability up to +/- 0.5 ℃, support 0-180 minutes timing and continuous digestion, with overheating protection and temperature alarm function.

$ 2302.00

Adopt 165 ℃ thermostatic digestion and spectrophotometric detection technology, detection range 0~ 20000mg/L, support digestion Colorimetric integrated tube design, built-in rechargeable battery, can store 4000 sets of data and support a variety of transmission interfaces.

$ 2526.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Colorimetric digestion integrated tube operation, no need to transfer liquid, Measurement range 0~ 250mg/L, detection limit of 0.5mg/L, multiple measurements of water samples to take the average value to reduce errors, suggesting detection of abnormalities.

$ 2913.00

Digestion determination does not affect the accuracy, equipped with PID automatic temperature control timing system, Optical inspection stability is less than 0.002A/20min, can store 30 standard Linear dispersion and 199 measurement values, IP65 protection design.

$ 1560.00

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Using sealing catalytic digestion and Colorimetry measurement, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, and the batch processing of 12 water samples is supported, and the operation is simple and time-saving.

$ 1114.00

Articles

Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity