Color Printing Ink Viscosity Tester

The color printing ink viscosity tester measures resistance by rotating a rotor in the ink, reflecting the ink's flow resistance. It is used to control the uniformity of ink transfer during printing, preventing blurring or color differences, and is applied in ink production and on-site testing in printing workshops.
Selection
When selecting, consider that the measurement range should cover common ink viscosity values, the accuracy should meet the requirements of process control, and it should be compatible with industry-standard measurement methods. The instrument's materials should be resistant to solvent corrosion, and it should be easy to operate for daily use. The temperature control function should adapt to different environmental conditions.

Terms

Standards

Instruments

Automatic ink running stability, ink time and speed can be set, printing pressure 0~ 2mm adjustable, provide low, medium and high three printing speed, each time can be proofed 4 colors to facilitate Color contrast.

$ 3430.00

The equipment supports 0-2MM pressure adjustment, providing three-speed printing speed (10/15/20 rpm) and uniform ink speed (650/800/1000rpm), which can imprint 2.5mm thick paper and 1mm plastic film to achieve precise uniform ink and stable operation.

$ 3381.00

The printing pressure can be adjusted accurately according to the thickness of the material, and the printing speed can be adjusted. It provides 4 primary color areas and 4 light color areas to ensure that the pattern is clear and tidy.

$ 4527.00

Can accurately test whether the surface tension is up to standard, support ink Color and tip shape customization, suitable for a variety of printing composite process.

$ 87.00

Driven by numerical control motor, swirl/spin accuracy of 0.1 degrees, support multi-color inks Hue, concentration detection, can anticipate dry and wet ink color change and Abrasion Resistance, 5-10 minutes rapid color development, significantly reduce inks waste.

$ 3107.00

It can simultaneously print color bars of different Colors or Ink Film thickness, detect inks Hue and Gloss, uniform ink time can be adjusted from 1 to 800 seconds, support dry and wet ink discoloration analysis and abrasion resistance testing.

$ 4367.00

Adopt automatic ink leveling system, ink leveling time adjustable, three-speed ink leveling speed 400-700rpm, printing speed 0-1000rpm frequency conversion adjustable, equipped with German imported rubber roller, support different materials substrate.

$ 3656.00

Can accurately test the material surface tension is up to standard, support custom ink Color and tip shape, suitable for a variety of printing composite process, specifications include 10ml to 500ml bottle.

$ 87.00

Can accurately test the material surface tension is up to standard, support custom ink Color and tip shape, suitable for a variety of printing composite process, specifications include 10ml to 500ml bottle.

$ 87.00

Provide uniform ink speed three adjustable 450 to 800rpm, color development speed three adjustable 12 to 25rpm, color development pressure range -20 to 80, support ordinary or UV ink roller, improve work efficiency and applicability.

$ 7658.00

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

The multi-stage color development structure can simultaneously print 4 color strips of different thicknesses or Hue, and the uniform ink speed can be adjusted by 500-800rpm in three gears. With the Basis Weight instrument, the ink layer thickness is precisely controlled, and the operation is simple and durable.

$ 5237.00

It can display 45 × 210mm and 106 × 210mm color bars simultaneously, providing 450-800 rpm ink leveling speed and 1-120 seconds ink leveling time adjustable, with built-in pressure adjustment to ensure accurate and stable color.

$ 7496.00

The printing speed is 0~ 260m/min, the accuracy is less than 0.5, which supports data management and characteristic detection, and can reduce the number of proofing and material waste.

$ 9433.00

Multi-color superposition sampling and color development at the same time, sampling can be done without boot printing, anilox roller adopts metal rubber roller structure, color development rubber roller Hardness 75 °, high processing accuracy and small amount of glue.

$ 267.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.