Pantone ColoriMeter

The Pantone colorimeter calculates L*a*b* chromaticity data by comparing the reflected light from an object with the values of color cards under standard light sources. It is used in industries such as coatings and plastics to control color consistency during production, avoiding deviations from visual judgment.

Instruments

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

Using D/8 lighting system, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration technology to ensure measurement accuracy, lithium battery supports 12,000 consecutive tests.

$ 202.00

It has a multi-function smart button design, supports more than 30 Color indicators and 28 kinds of observation Illuminants, adopts non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 is less than 0.2, high measurement Stability, portable and lightweight only 88 grams.

$ 267.00

Adopt internationally recognized LOVIBOND color scale, measurement range red 0.1-79, yellow 0.1-79, blue 0.1-49 LOVIBOND units, minimum indication 0.1, equipped with three specifications Cuvette to meet multi-sample testing needs.

$ 677.00

Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.

$ 1687.00

Equipped with a 3.5-inch touchscreen, with repeatability of △E*ab ≤ 0.03, measurement accuracy of 0.01, built-in multiple electronic color cards, supports various color difference formulas and color spaces, facilitating quick color matching and comparison.

$ 231.00

1000 wire precision blazing grating and silicon Photocell, photovoltaic cell array, Optical inspection resolution less than 10nm, can simultaneously measure SCI/SCE Light spectrum, Inter-instrument Agreement Delta E * ab < 0.15, equipped with camera positioning and stabilizer platform.

$ 4398.00

1000 wire precision blazing grating and silicon Photocell, photovoltaic cell array, Optical inspection resolution less than 10nm, can simultaneously measure SCI/SCE Light spectrum, Repeatability Delta E * ab within 0.03, support dual aperture switching and camera positioning.

$ 6012.00

Featuring a 3.5-inch touchscreen for easy operation, it offers a measurement accuracy of 0.01 and a repeatability of ΔE*ab ≤ 0.03. Equipped with multiple built-in color cards for fast matching, it supports various color difference formulas and cloud-based data sharing.

$ 231.00

Fully automatic one-click measurement of a variety of whiteness paraMeters, support chromaticity coordinates ≤ 0.001 High Accuracy, built-in thermal printer and RS232 interface, suitable for powder, paper and other samples.

$ 1818.00

With camera view function to prevent measurement deviation, Repeatability Delta E * ab 0.05, Support SCI and SCE dual Measurement mode, store 20000 data, suitable for a variety of environment operation.

$ 3543.00

With camera viewing function to prevent measurement deviation; Repeatability Standard Deviation Delta E * ab within 0.05; dual measurement diaMeter 4mm and 6mm optional; Support SCI and SCE simultaneous measurement, Storage capacity up to 20,000 data.

$ 3543.00

Utilizing a full-spectrum LED light source and a spectral sensor with a wavelength range of 400-700nm, it is equipped with a 3.5-inch capacitive touch screen, built-in multiple color cards, achieving a color card matching accuracy of over 90%, and capable of measuring various color parameters.

$ 651.00

Featuring a 20mm large aperture design, it enables uniform measurement of textured and rough surfaces; repeatability ΔE*ab ≤ 0.03 ensures high precision; equipped with a touchscreen and color card matching for convenient operation, supporting multiple color difference formulas and color spaces.

$ 490.00

With camera viewing function to prevent measurement deviation, Repeatability Standard Deviation Delta E * ab within 0.05, dual Measurement mode synchronously displays SCI and SCE results, large storage space can store 20,000 data.

$ 3543.00

Articles

The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Reflectometer for measuring the hiding power of colored paint coatings
This article introduces the method of using a reflectometer to measure the hiding power of colored paint coatings. Hiding power refers to the ability of a coating to conceal differences in the underlying color. Traditional methods relying on visual judgment are prone to subjective influences, while instrumental measurement offers greater objectivity and accuracy.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.