Oil water Tank coating thickness Gauge

The oil/water tank coating thickness gauge employs magnetic induction or eddy current principles, measuring coating thickness through changes in magnetic flux or eddy current effects between the probe and the substrate. It is used to detect the thickness of anti-corrosion coatings in ship oil and water tanks, ensuring compliance with construction specifications. Applications include coating quality control in shipyards and thickness verification during maintenance and repairs.
Selection
When selecting, consider the substrate material to choose between magnetic induction or eddy current models. The oil tank environment requires explosion-proof certification. Use a small probe for curved surface measurements. Select the measurement range based on the coating thickness range. Opt for a wear-resistant probe for long-term use. Compare on-site measurement data with the instrument's accuracy parameters.

Terms

Instruments

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

With dual-use function of water and oil, Temperature Uniformity up to +/- 0.05 ℃, Flow rate of external circulation pump 6L/min, liner with S304 stainless steel, Safety protection including power failure and low water level alarm.

$ 816.00

The equipment has a 15-liter large-capacity water Tank and an 8mm inner diaMeter water pipe, supports 0 to 99 hours of time control, adopts stainless steel structure and automatic control device, and is suitable for coating stain resistance testing.

$ 369.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Water and oil dual-use Temperature range Room temperature to 200 ℃, Temperature Uniformity +/- 0.05 ℃, with internal and external circulation system and multiple Safety protection, the use of heat-free centrifugal pump to avoid affecting the temperature field uniformity.

$ 761.00

Water-oil dual-use design, Temperature Uniformity up to +/- 0.05 ℃, support external circulation function, Pump Flow rate 6L/min, with multi-Safety protection and optional program temperature control.

$ 562.00

The equipment supports water and oil dual-use, Temperature range from room temperature to 300 ℃, capacity 40L, using PID automatic temperature control and High Accuracy PT100 Sensor to ensure stable and uniform temperature, with domestic circulation system to avoid heat impact, Safety protection function is complete.

$ 1148.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump and domestic circulation system, to ensure temperature stability and flow field uniformity, support a variety of Safety protection.

$ 559.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range to 100 ℃, External circulation pump Flow rate 6L/min, Built-in Safety protection and optional program temperature control, suitable for a variety of experimental needs.

$ 1416.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.