Coaxial single-cylinder viscoMeter

The coaxial single-cylinder viscometer drives a rotor to rotate in the sample via a motor, measuring the resistance of the fluid to the rotor to calculate viscosity. It is used for quality control of fluids such as coatings and inks, detecting their flow characteristics.
Selection
When selecting, consider the compatibility between the sample viscosity range and the instrument's measurement range, ensuring that the rotor size is appropriate for the sample volume. Pay attention to temperature control requirements and ensure material compatibility. Refer to industry standard method requirements.

Terms

Standards

Instruments

Using coaxial cylinder structure with a small number of sample adapters, only 7.8-11 ml sample volume, Measurement accuracy +/- 2%, equipped with dual RS232 interfaces to directly connect printers and computers.

$ 1038.00

The coaxial cylinder structure is used to achieve accurate viscosity measurement. The sample dosage is only 10-20mL. It is equipped with a removable sample Cup for easy replacement and cleaning. It supports a variety of rotor models to cover a wide range of viscosity.

$ 317.00

Using coaxial cylinder structure with a small number of sample adapters, the sample volume is only 7.8-11 ml, Measurement accuracy +/- 2%, equipped with dual RS232 interface can be directly connected to the printer and computer for data output.

$ 1077.00

The coaxial cylinder structure is used to achieve accurate viscosity measurement under the specified shear rate, the sample volume is only 10-20mL, and the water Bath jacket can keep the temperature uniform and stable. It supports a variety of rotor models covering a wide measurement range.

$ 432.00

Using coaxial cylinder structure, the sample volume is only 7-13ml, Measurement accuracy +/- 2%, equipped with RS232 interface to connect printers and computers, suitable for testing a small number of precious samples.

$ 1001.00

Using coaxial cylinder structure, the sample volume is only 7-13ml, the Measurement accuracy is +/- 2%, equipped with timing function and RS232 interface, suitable for small sample testing.

$ 1153.00

The planetary coaxial coaxial fretting focusing device is used for comfortable and stable focusing; the total magnification is 40X-1600X, and it is equipped with a liftable Abbe condenser and a double-decked mechanical stage to observe unstained specimens clearly.

$ 1977.00

Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.

$ 183.00

Adopt stepper motor direct drive gearless design, the speed is accurate and stable; single-turn multiple sampling technology ensures measurement conformity; viscosity range 1~ 5000mPa · s to 1000000mPa · s, repRoducibility +/- 0.5% F.S.

$ 1424.00

Using Hastelloy heating cylinder to avoid high temperature oxidation, dual Sensor temperature control accuracy of +/- 0.5 ℃, support strong corrosion plastic test, with four minutes countdown and RS232 data output function.

$ 933.00

The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.

$ 204.00

Digital PID Temperature Control system, temperature control accuracy of +/- 0.2 ℃, the upper and lower heat head independent temperature control, double cylinder synchronous circuit to ensure pressure Balance, heat cover heating uniform, support manual and foot pedal dual operation mode.

$ 1656.00

Hollow self-resetting hydraulic cylinder design, center aperture 18mm, maximum pull-out force 20kN, compact structure and can be connected by quick connector, suitable for a variety of anchorage inspection.

$ 562.00

Hollow cylinder center aperture 85mm, maximum working capacity 800KN, piston Travel 150mm, compact structure easy to carry, manual pump with double pressure Operating Mode.

$ 1861.00

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.
Rotational viscometer measures the viscosity of paint at low shear rates.
This article introduces the method and significance of measuring the viscosity of colored paint at low shear rates using a rotational viscometer.
Standard Method for Measuring the Melt Viscosity of Hot Melt Adhesives with a Rotational Viscometer
This article introduces the standard method for measuring the molten viscosity of hot-melt adhesives using a rotational viscometer. During the measurement, the hot-melt adhesive sample must be fully melted and degassed, placed into a measuring cup, and then measured with the rotational viscometer at a set temperature.
The cone and plate viscometer measures the rheological properties of a small amount of ink sample.
A cone-plate viscometer measures torque through rotation between the cone and plate, enabling the analysis of rheological properties with small ink samples. It is suitable for small-volume measurements, reducing interference from solvent evaporation.