Permanently Fixed IR ThermoMeter

The fixed infrared thermometer detects the infrared radiation emitted from the surface of an object and converts it into a temperature reading. It is used for non-contact measurements, monitoring surface temperatures in industrial processes such as paint drying and plastic molding, avoiding direct contact that could affect the material.
Selection
When selecting a fixed infrared thermometer, it is essential to consider a measurement range that covers application requirements, a response time that matches process speed, an installation method suitable for the on-site environment, and to pay attention to the emissivity characteristics of the target material to ensure accurate readings.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

Using irreversible discoloration technology, the rated temperature is 82 ° C, Dimensions 12 * 12mm, Color changes permanently after overheating and has recording function, in line with industry technical standards.

$ 81.00

Using irreversible discoloration technology, Color changes permanently after overheating, providing reliable recording; Rated temperature 143 ℃, size 12 * 12mm, easy to paste and strong gluing.

$ 81.00

Using irreversible discoloration mode, with three-grid temperature measurement, covering the range of 37 ° C to 42 ° C, easy to paste and permanently record the overtemperature after discoloration.

$ 83.00

Using irreversible discoloration technology, it provides five-speed temperature monitoring from 132 ° C to 154 ° C, easy to paste and permanently record temperature changes after discoloration.

$ 87.00

Using irreversible discoloration technology, it has three-grid temperature monitoring capability. Measurement range is 43 ° C to 49 ° C. It is firmly pasted and permanently records temperature changes after discoloration.

$ 83.00

Using irreversible discoloration technology, it has three-grid temperature detection capability, covering the range of 138 ° C to 149 ° C, firmly pasted and can permanently record over-temperature conditions.

$ 83.00

Equipped with special fixed load weight, the total mass is about 1kg, and the downward pressure speed is 3.2mm/s, which can improve the Stability and accuracy of rubber Hardness measurement.

$ 199.00

Fixed Rotation speed 2800RPM, eccentric spherical shaft design for easy installation of vibration head, reinforced engineering plastics and TPU table, acid and alkali wear resistance, support point and continuous Operating Mode.

$ 189.00

Equipped with fixed load weight and adjustable horizontal table, column lifting space ≤ 140mm, using Glass table anti-rust wear, can accurately adjust the level of the platform, improve the test Repeatability and accuracy.

$ 164.00

Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.

$ 2494.00

Equipped with a 1kg fixed load weight, pressing the specimen at a speed of 3.2mm/s, providing stability testing conditions, suitable for standard Hardness measurement, preventing vibration from affecting the results.

$ 235.00

Using aluminum alloy chuck and stainless steel pole, baseplate size 290 * 210mm, pole height 780mm, suitable for 16mm Cube lifting fixed clip, stable and durable structure.

$ 178.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.

$ 2368.00

The eccentric spherical shaft design ensures uniform mixing, and the fixed speed of 2800RPM realizes fast vortex mixing. The TPU material countertop is wear-resistant and corrosion-resistant, small in size and low in noise.

$ 190.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.

$ 2494.00

Articles

Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Rotational Viscometer vs. Stormer Viscometer: How to Choose the Right Instrument Based on Coating Type
The rotational viscometer measures viscosity by detecting rotor torque and can analyze rheological properties at different shear rates, making it suitable for research and precise measurements. The Stormer viscometer uses the load at a fixed rotational speed to determine the KU value, simulating construction conditions, and is commonly used for rapid on-site evaluation of coating application performance.