Eddy Current Conductivity Tester Pen

The eddy current conductivity test pen operates based on the principle of electromagnetic induction. It generates an alternating magnetic field at the pen tip, which induces eddy currents upon contact with metal materials to measure conductivity values. It is used for rapid detection of the electrical conductivity of metal materials and is commonly applied in non-ferrous metal sorting, alloy identification, and quality control.
Selection
When selecting, consider that the measurement range should cover common metal conductivity, the tip size should match the shape of the test piece, and the instrument should have temperature compensation functionality. Focus on ease of calibration and data storage capabilities, ensuring the instrument is lightweight, durable, and suitable for on-site operating environments.

Terms

Standards

Instruments

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, error +/- 3%, support single and continuous Measurement mode, automatic identification of matrix material and memory calibrated value, easy to operate.

$ 401.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.

$ 275.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.

$ 525.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.

$ 419.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support continuous single two Measurement mode, with automatic statistics and storage function, metal shell anti-interference.

$ 425.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500μm, resolution 10μm, wear-resistant hard metal probe and Automatic calibration memory function, support USB data communication and automatic shutdown.

$ 240.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, resolution 0.1μm, with 500 sets of Data storage, over limit alarm and automatic shutdown function, split Probe design is easy to operate on site.

$ 280.00

Integrated magnetic Induction and eddy Current dual technology, automatic identification of the substrate and conversion, Measurement range 0-1500μm, accuracy +/- 2%, Probe life more than 500,000 times, adapt to complex environment.

$ 227.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500μm, support continuous single two Measurement mode, with 500 sets of data storage and thermal printing function, the error is only +/- 3%.

$ 385.00

Articles

Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Classification standards for determining the hardness of coatings using a pencil hardness tester.
This article introduces the method of measuring the hardness of coatings using a pencil hardness tester. It involves using pencils of varying hardness to scratch the coating and observing whether scratches are produced to determine the hardness grade, ranging from 6B to 9H.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Key Operational Points and Influencing Factors of Pencil Hardness Method for Determining Coating Film Hardness
The pencil hardness test is a method used to evaluate the scratch resistance of a coating by making marks on the paint film with pencils of known hardness. During the operation, a uniformly cured sample is prepared, and calibrated pencils are used to make marks at a 45-degree angle with a fixed force, aiming to identify the highest hardness grade that does not scratch through the paint film.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.