Environmental Temperature and Humidity Meter

Environmental temperature and humidity meters detect air temperature and relative humidity through sensors, converting physical quantities into electrical signals for display. They are used to monitor environmental conditions in places such as laboratories and warehouses, helping to control material storage and production processes.
Selection
When selecting, consider the measurement range covering the usage scenarios, accuracy meeting the requirements, and response time adapting to the rate of change. Pay attention to sensor types such as capacitive hygrometers and thermocouple thermometers, and evaluate calibration cycles and protection ratings.

Terms

Standards

Instruments

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.

$ 4138.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.

$ 5110.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.

$ 16459.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.

$ 14388.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.

$ 6194.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.

$ 8857.00

Temperature range -60~ 150 ℃, Humidity control accuracy +/- 3% R.H., non-fluorine environmental protection refrigerant and independent temperature limit alarm system, with multi-stage programmable control and Interface function.

$ 6983.00

Temperature range -60~ 150 ℃, humidity control 30~ 95% R. H; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control function, support data export and remote monitoring, to ensure the accuracy and stability of the test process.

$ 13796.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% RH, with multi-stage programming and PID automatic calculation function, support data export and analysis, built-in safety alarm system to ensure stable operation.

$ 15374.00

Temperature range -60~ 130 ℃, humidity control 30~ 95% RH, non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 7377.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with color Touchscreen and 100 sets of program presets, with independent temperature limit alarm and multiple Safety protection functions.

$ 14487.00

Environmental friendly refrigerant design, Temperature Uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with intelligent Touchscreen controller and multiple safety protection system to ensure stable and reliable experimental environment.

$ 3436.00

Articles

Detection Methods and Standards for Ozone Aging Tests on Thin Films
This article primarily introduces the aging test method for thin-film materials in an ozone environment.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
Application of Coating Rate Cardboard in the Determination of Coating Rate for Architectural Coatings
Coating rate card paper is a standardized substrate used to determine the spreading rate of architectural coatings. It features a smooth surface and stable parameters, which help minimize the influence of substrate variations and environmental factors associated with traditional methods.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.