Oil Pump High and Low Temperature Test Chamber

The high and low temperature test chamber for oil pumps simulates extreme temperature environments through refrigeration and heating systems to test the working performance and durability of oil pumps under high and low temperature conditions. It is used in industries such as automotive and machinery for quality verification of oil pump products.
Selection
When selecting, consider that the temperature range covers actual usage needs, the chamber size accommodates the size of the oil pump being tested, the temperature control accuracy meets testing standards, the equipment materials are corrosion-resistant and comply with safety regulations, and the operating energy consumption and maintenance costs are moderate.

Terms

Standards

Instruments

The integrated pump body structure is adopted, and the forced oil pump lubrication is controlled. The ultimate pressure can reach 0.005mbar, the noise is as low as 58dB, and the parts are few and easy to maintain.

$ 698.00

The integrated pump body structure is adopted, and the oil pump is forced to lubricate and control. The ultimate pressure is as low as 0.005mbar, the noise is only 58dB, and the parts are few and easy to maintain.

$ 2250.00

The integrated pump structure is adopted, and the forced oil pump lubrication system ensures stable operation. The ultimate pressure can reach 0.005mbar, and the noise value is only 58dB. The special gas ballast valve is designed to effectively extract steam without polluting the oil quality.

$ 645.00

The integrated pump body structure is adopted, and the forced oil pump lubrication system ensures stable operation. The ultimate pressure is as low as 0.005mbar, the noise is only 58dB, and the parts are few and easy to maintain.

$ 762.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -20~ 100 ℃, fluctuation value +/- 0.1 ℃, built-in pressure suction pump maximum Flow rate 22L/min, support short time idling and low level protection function.

$ 2504.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

Adopt oil pump forced oil inlet device, can operate continuously under 1.33 × 10 ³ Pa intake pressure, gas distribution ballast to prevent pump oil mixing, pumping speed 2L/S, Ultimate vacuum degree up to 0.006mbar, support a variety of interface conversion.

$ 375.00

Adopt proportional refrigeration technology and high temperature direct drop technology, temperature fluctuation +/- 0.1 ℃, pump maximum Flow rate 22L/min, support short time idling and low liquid level protection, long service life.

$ 2136.00

Temperature range -20~ 100 ℃, cooling capacity 700W, built-in pressure suction pump Flow rate up to 22L/min, support high temperature direct drop and short-term idling of the pump head, long service life.

$ 1890.00

Using oil-free vacuum pump to achieve pollution-free work, with three-speed Vacuum Level conversion and 0.01s high resolution, intelligent pneumatic pressure to ensure Test accuracy and efficiency.

$ 2612.00

Using electromagnetic motor and diaphragm sealing Chamber, Vacuum Level up to 0.08Mpa, pumping rate 60L/min, non-oil pump design pollution-free, full Teflon material resistant to strong acid and alkali corrosion, free of daily maintenance.

$ 388.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Proportional refrigeration technology and PID technology, Temperature range -40~ 100 ℃, built-in pressure suction pump Flow rate up to 22L/min, support high temperature direct drop and short time idling protection, long service life.

$ 2136.00

The ultimate pressure is as low as 0.005mbar, the noise is only 58dB, and the integral pump structure and forced oil pump lubrication system are adopted to ensure high reliability and quiet operation, which is convenient for maintenance.

$ 933.00

Proportional refrigeration and PID technology, equipped with 22L/min large Flow rate pump, support high temperature direct drop and short-term idling protection, temperature fluctuation only +/- 0.5 ℃, adapt to 80~ 300 ℃ high temperature environment.

$ 1915.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.