Manual Handheld Film Applicator

A manual film applicator evenly spreads the coating into a wet film of specified thickness by moving a metal rod or blade across the substrate at a constant speed. It is used in laboratories to simulate coating processes and test properties such as leveling and hiding power of coatings.

Instruments

Using formed process, film thickness 29.7 μ m, diaMeter 9.52mm, total length 400mm, application width 300mm, stainless steel material, no wire-wound design.

$ 167.00

With four film Film thickness, Spreader width 160mm, wear-resistant corrosion-resistant alloy steel material, can precisely control wet-film or dry-film thickness, ensure coating conformity and Repeatability.

$ 217.00

Effective Spreader width 100mm, wet film thickness up to 600μm, high-quality wear-resistant corrosion-resistant alloy steel material, support manual film or with automatic Film Applicator to ensure good conformity Repeatability coating.

$ 143.00

Spreader width 100mm, wet film thickness 50μm, wear resistant corrosion resistant alloy steel material, suitable for manual or automatic Film Applicator, can be prepared uniform film for performance testing.

$ 143.00

Spreader width 100mm, wet film thickness 60μm, high-quality wear-resistant corrosion-resistant alloy steel material, manual film can also be equipped with automatic Film Applicator, support non-standard customization.

$ 143.00

Using 180 * 480mm size, with wire Rod or Film Applicator scraping ink, is conducive to the film flat and effective, improve film mass.

$ 122.00

Adopting 500 * 700mm Dimensions, used with bar or Film Applicator, is conducive to the smooth and effective film, and improves the convenience of film operation.

$ 227.00

Hardness stainless steel material, Hardness of 50~ 55HRC, film accuracy +/- 2μm, smooth surface to support a variety of Spreader requirements, can be used with Film Applicator to achieve automatic film operation.

$ 162.00

Film accuracy of +/- 2μm, high hardness stainless steel material, hardness value of 50~ 55HRC, smooth surface and support a variety of Spreader width and Film thickness specifications to ensure film accuracy and durability.

$ 194.00

Using a formed pRoduction process, the film Film thickness is as thin as 4.6μm, the accuracy is up to 0.1 micron, and the effective Spreader width is 30cm. It can be used with an automatic Film Applicator and has the advantage of continuous wire.

$ 186.00

Spreader width 100mm, wet film thickness 40μm, wear resistant corrosion resistant alloy steel material, can be manually operated or with automatic Film Applicator to ensure coating conformity and Repeatability.

$ 143.00

Double-sided design can be coated with two pre-order film thicknesses 90 and 150 μm, Spreader width 20mm, suitable for Automatic Film Applicator and Drying Time Recorder, in accordance with ASTM D 823 standard.

$ 1455.00

Formed to achieve 52.6 micron precision film, 304 stainless steel material provides high Abrasion Resistance, 50mm at both ends of the hand part without additional handle, can be directly matched with the experimental Film Applicator.

$ 167.00

Film Film thickness 175μm and 200μm optional, Spreader width 80mm, accuracy of +/- 2μm, using high Hardness wear resistant stainless steel material, by three coordinate inspection to ensure accurate size.

$ 162.00

Spreader width 100mm, wet film thickness 37.5μm, wear-resistant corrosion-resistant alloy steel material, can be used manually or with automatic Film Applicator to ensure coating conformity and Repeatability.

$ 143.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Standards and Equipment Selection for Drop Testing in Mobile Phone Whole-Machine Reliability Testing
Drop test is an important method to test the durability of mobile phones, simulating accidental drops in daily life to examine the impact resistance of components such as the casing and screen. The test must follow international or industry standards, specifying conditions such as drop height and number of times.
Selection Comparison between Automatic and Manual Proofing Methods for Ink Proofing Machines
This article compares manual and automatic proofing methods for ink proofing machines. Manual proofing relies on the operator's experience, offering flexibility and lower initial costs, but it suffers from poor consistency, making it suitable for research and development or low-frequency usage.
The softness tester can show a data difference of up to 30% when measuring paper hand-feel samples taken from different directions.
This article mainly discusses that when testing the softness of paper, if samples are taken along different directions, such as the machine direction (longitudinal) and the cross direction (transverse), the measured data can vary significantly, sometimes by as much as 30%.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.
Inventory of Laboratory Coating Instruments
Laboratory coating tools include gap coaters, wire rods, automatic coating machines, etc. What are the differences between them? This article will tell you!