Micro Pipette

Micro pipettes utilize a piston to create negative pressure within a capillary tube, enabling the precise transfer of microliter-level liquids through disposable tips. They are commonly used in laboratory settings for quantitative sample addition, dilution, and mixing operations, particularly in biochemical analysis and cell culture.
Selection
When selecting, consider the range matching the experimental requirements, check the accuracy error range, and confirm tip compatibility. The material should be chemically resistant, comfortable to handle, and easy to maintain and calibrate. Refer to feedback from peers and the brand's after-sales service.

Terms

Instruments

Continuous adjustable micro sampling, range 2-20ul, accuracy error +/- 0.90%, nozzle ejector removable for high temperature and high voltage disinfection and cleaning maintenance.

$ 89.00

Capacity 1000ul, Minimum Encasement 500 pcs/pack, Sterile design to ensure experimental accuracy, suitable for a variety of Pipette use.

$ 77.00

The 15-hole design is suitable for 10ml suction heads, which are specially matched for HYD-1WB Pipette to ensure accurate and stable pipetting process and improve experimental operation efficiency.

$ 79.00

Continuous adjustable micro sampling, range 0.1~ 2.5μL, accuracy error +/- 2.50%, nozzle ejector removable for high temperature and high voltage disinfection and cleaning maintenance.

$ 88.00

The 10ul capacity specification is used with the standard Pipette, and each pack of 1000 packs meets the needs of batch experiments. The transparent material is convenient for observing the liquid level.

$ 77.00

Capacity 10ml, minimum Encasement 100 pcs/pack, sterile independent Encasement to ensure experimental cleanliness, conical design to ensure airtightness, suitable for a variety of brands Pipette use.

$ 89.00

The 96-hole design is suitable for a variety of Pipette models, and the 200ul capacity meets the needs of routine experiments to ensure that the suction heads are neatly stored and easy to use.

$ 76.00

The 96-hole design is adopted, with a capacity of 10ul, and it is suitable for HYD-0.1B/0.5B Pipette to ensure stable placement and quick access of the suction head, which improves the efficiency and accuracy of the experiment.

$ 76.00

Range 1-10ml, accuracy error +/- 0.60%, nozzle ejector removable and high temperature and high voltage sterilization, easy to clean and maintain, with lightweight design and clear reading window.

$ 89.00

The 60-hole design is suitable for 1ml suction heads, which are specially optimized for HYD-100B Pipette to ensure stable storage and quick access of the suction heads, and improve the experimental efficiency.

$ 76.00

The 28-hole design can accommodate 5ml suction heads and is suitable for HYD-1000B Pipette to ensure that the suction heads are stored in an orderly manner and easy to use, improving the experimental efficiency.

$ 79.00

Continuously adjustable micro-pipetting, range 10-100ul, accuracy error +/- 0.80%, nozzle ejector removable for high temperature and high voltage disinfection cleaning and maintenance.

$ 89.00

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.

$ 267.00

Range 1-5ml, accuracy error +/- 0.50%, nozzle ejector removable and high temperature and high voltage disinfection, easy to clean and maintain, light operation.

$ 89.00