Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.
Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.
Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
Temperature range -60~ 150 ℃, humidity control range 20~ 98% R.H., with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring, to meet the needs of complex environment testing.
With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, multi-wing air supply circulation to ensure uniform temperature and humidity, support LAN interface remote monitoring and data export.
Multi-wing air supply cycle is used to ensure uniform temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, to meet a variety of industrial standard testing requirements.
Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 program control capacity, support automatic calculation and fault self-diagnosis function, using cascade refrigeration system to ensure stable performance.
Using Japanese Panasonic Compressor and binary low temperature circuit system, temperature control accuracy of +/- 0.5 ℃, equipped with stainless steel humidifier and nickel-chromium alloy heater, support programmed test and data recording function, to meet the demanding environment simulation needs.
Temperature range -40 ℃~ 150 ℃, Temperature Uniformity ≤ 2 ℃, using double-decked vacuum Glass observation window and Japan Panasonic Compressor, with USB Interface and program control function.
Using Japan Panasonic Compressor and binary low temperature circuit system, Temperature range -70 ℃~ + 150 ℃, Temperature Uniformity ≤ 2 ℃, equipped with double-decked vacuum Glass observation window and automatic water replenishment device.
Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.