Temperature and Humidity Cyclic Chamber

The temperature and humidity alternating chamber simulates various temperature and humidity conditions within a sealed space through its refrigeration, heating, humidification, and dehumidification systems. It is used to test the performance changes of materials under cyclic variations in temperature and humidity, commonly applied in product aging tests, quality inspections, and environmental adaptability assessments.
Selection
When selecting, ensure the temperature and humidity range covers the testing requirements, with fluctuations controlled within ±0.5℃ and ±2% RH. The chamber volume should be determined based on the sample dimensions, and the interior should feature a corrosion-resistant stainless steel lining. The compressor must meet the required cooling rate, and the programmable controller should support multi-segment curve programming. Pay attention to the anti-condensation design of the observation window and the configuration of test ports.

Terms

Standards

Instruments

Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.

$ 5307.00

Temperature range -60~ 130 ℃, humidity control 30~ 95% RH, non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 7377.00

Temperature range -60~ 150 ℃, Humidity control 30~ 95% R.H., non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 6588.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% R. H, using programmable multi-stage control and independent temperature limit alarm system, equipped with test holes and can be pulled out of the water Tank for easy operation.

$ 9843.00

Temperature range -40~ 150 ℃, humidity control 30~ 95% R.H., non-fluorine environmental protection refrigerant and imported Compressor, with independent temperature limit alarm system, support multi-stage programmable control.

$ 16459.00

Temperature range -40~ 150 ℃, Humidity control 30~ 95% R. H, Temperature Uniformity +/- 2 ℃. Using fluorine-free environmental protection refrigerant and imported Compressor, support multi-stage programming and data processing, with independent temperature limit alarm and a variety of Safety protection functions.

$ 5307.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Temperature range -40~ 150 ℃, Humidity range 30~ 95% RH; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and multiple Safety protection functions.

$ 7574.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% RH, equipped with imported Compressor and programmable Touchscreen, support multi-stage program control and real-time data recording, with independent temperature limit alarm and multiple Safety protection functions.

$ 7969.00

Temperature range -60~ 150 ℃, humidity control 30~ 95% R. H; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control function, support data export and remote monitoring, to ensure the accuracy and stability of the test process.

$ 13796.00

Using imported Compressor and environmental protection refrigerant, temperature control accuracy +/- 0.5 ℃, equipped with color Touchscreen controller, support multi-stage programming and remote monitoring, with multiple Safety protection functions.

$ 9941.00

Adopt imported Compressor and environmental protection refrigerant, temperature control accuracy +/- 0.5 ℃, equipped with multiple Safety protection system, can preset 100 sets of programs to meet complex testing needs, test hole design is convenient for experimental operation.

$ 4419.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with color Touchscreen and 100 sets of program presets, with independent temperature limit alarm and multiple Safety protection functions.

$ 14487.00

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% R.H., with multi-stage heating pipe and circular split humidifier, with energy-saving regulating valve to achieve segmented control, ensure uniform and stable heat preservation Humidity.

$ 2736.00