Eddy current metal coating thickness Gauge

Eddy current metal coating thickness gauges generate a high-frequency electromagnetic field through the probe, inducing eddy currents in the metal substrate. The thickness of the coating alters the eddy current response, and the instrument measures the impedance changes to calculate the thickness. They are used for measuring insulating coatings on non-magnetic metal substrates such as aluminum anodizing and copper foil coatings.
Selection
When selecting, confirm the conductivity of the substrate. Non-ferrous metals such as aluminum and copper are suitable. Consider the material of the coating; insulating coatings like anodized layers are applicable. Choose a matching probe based on whether the surface is curved or flat, and check whether the instrument's calibration range covers the expected thickness. Note the impact of environmental temperature on measurement stability.

Instruments

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support continuous single two Measurement mode, with automatic statistics and storage function, metal shell anti-interference.

$ 425.00

The eddy Current principle is used for measurement of nonconductive coatings on non-ferrous metal substrates, with a thickness range of 0~ 625μm and an error of +/- 3%. It has IP65 Protection Rating and fast measurement capabilities of more than 60 readings per minute.

$ 1338.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500μm, resolution 0.1μm, Probe wear-resistant more than 500,000 times, support galvanized Grammage and thickness switching display, suitable for various metal matrix detection.

$ 319.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.

$ 275.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.

$ 170.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, resolution 0.1μm, can store 99 sets of data and support USB and Bluetooth transmission, equipped with wear-resistant hard metal probe.

$ 525.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.

$ 525.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500μm, resolution 10μm, wear-resistant hard metal probe and Automatic calibration memory function, support USB data communication and automatic shutdown.

$ 240.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, resolution up to 0.1μm, equipped with wear-resistant hard metal probe and spring guide sleeve Probe, support automatic memory calibrating and RS232C communication.

$ 354.00