Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.
Temperature range -10~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, low noise, fast cooling, with over-temperature alarm and liquid level protection function, support multi-stage programming and data processing interface.
With +/- 0.1 ℃ temperature fluctuation and 0.1 ℃ resolution, built-in circulating water pump supports internal and external circulation, integrated over-temperature alarm and 9999 minutes timing function to ensure stable and efficient experiment.
Temperature range -50~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with over-temperature low temperature sound and light alarm and liquid level protection, support multi-stage programmable control, circulating pump Flow rate 8L/min, to ensure the safe and stable operation of the sample.
Temperature Fluctuation +/- 0.1 ℃, Temperature range + 5~ 99 ℃, with Sensor fault alarm and over-temperature protection function, built-in circulating water pump supports internal and external thermostatic water flow output.
Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.
Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.
The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.
Temperature range -40~ 100 ℃, accuracy up to +/- 0.02 ℃, support 7 groups of 63 steps programmable settings, circulating pump Flow rate 8L/min, with over-temperature alarm and liquid level protection to ensure safe and reliable experiments.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.