Laboratory film thickness Gauge

The laboratory film thickness gauge measures coating thickness through probe contact or non-contact methods, utilizing principles such as electromagnetic induction, eddy currents, or optical interference to calculate film layer data, and is used for quality inspection, research and development, and process control.
Selection
When selecting, consider the compatibility between the substrate type and coating characteristics, determine whether to use contact or non-contact measurement methods based on accuracy requirements and sample shape, and evaluate equipment functionality and maintenance costs in conjunction with the budget.

Terms

Standards

Instruments

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.

$ 127.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.

$ 186.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Using mechanical measurement method, Measurement range 0~ 1mm, accuracy ≤ 0.005mm, Graduation 0.001mm, probe diaMeter Φ 5mm, suitable for flat film and sheet, providing two probe pressure options.

$ 267.00

The three-wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-100 μm and a Graduation of 5 μm, which can be used for nondestructive measurement on planes and surfaces.

$ 186.00

Made of precision stainless steel, with a range of 50 to 950 μm, the 10-step tooth design can accurately measure wet film thickness, ensure painting mass and avoid material waste.

$ 109.00

Made of stainless steel, the range is 10~ 100μm, Division 10μm, Dimension 65 * 36 * 1.5mm, suitable for Paints, varnish and other Coating Coating thickness measurement.

$ 119.00

Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.

$ 401.00

The three wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-1000 μm and a Graduation of 50 μm. Destructiveness measurement can be carried out on the curved surface, and the operation is simple and high accuracy.

$ 186.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Discussion on the Relationship Between Speed Gradient and Film Thickness in Spin-Coating Film Formation
Spin coating is a common technique that uses centrifugal force to evenly spread droplets across a substrate to form a thin film. The film thickness is influenced by multiple factors, among which the gradient of spin speed and time is a key parameter. This study, based on fluid mechanics principles and experimental validation, analyzes the quantitative effect of the spin speed gradient on film thickness.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Operating specifications for on-site measurement of coating wet film thickness using wet film combs
This article introduces the operational standards for on-site measurement of coating wet film thickness using a wet film comb gauge. First, it explains the measurement principle of the wet film comb gauge, which involves estimating the thickness by observing the extent to which the teeth of the gauge are coated with the paint.
Test card paper for coatings is used for evaluating the appearance and film thickness consistency of coatings.
Coating test card is an integrated testing tool used to evaluate the appearance and film thickness uniformity of coatings.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Principles and Selection of Film Thickness Measurement Instruments
This article introduces the principles and selection methods of thin film thickness measurement instruments. The measurement principles are mainly divided into contact and non-contact methods, which calculate thickness by detecting the differences in the thin film's response to physical signals.
The correct method for using a wet film thickness gauge.
The wet film thickness gauge is used to measure the thickness of uncured coatings. It determines the value by reading the scale through contact with the wet film using a toothed structure, which is crucial for controlling dry film thickness and estimating material usage.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.