304 stainless steel liner and double circulation air duct system, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, with 0~ 9999 minutes timing function, suitable for drying, baking and other non-flammable and explosive materials processing.
Adopt air duct circulation system to automatically discharge water vapor, Temperature uniformity is better. Temperature range RT + 10~ 300 ℃, volume up to 220L, with over-temperature protection and timing function.
Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.
Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.5 ℃, hot air circulation system to ensure uniform temperature in the studio, with timing function and independent temperature limit alarm system.
Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 2 ℃, with overheating alarm and timing function, low noise hot air circulation system to ensure uniform drying, optional RS-485 interface connection recorder.
Using microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, Temperature Uniformity +/- 3%, hot air circulation system to improve Temperature uniformity, independent temperature limit alarm system to ensure safe operation of the experiment.
Temperature control accuracy of +/- 1 ℃ and uniformity of +/- 2 ℃, using low noise hot air circulation system directly drying objects, with over-temperature alarm and 1-9999 minutes timing function, support RS-485 communication interface to record data.
Low noise fan and single air duct design ensure Temperature Uniformity 2.50%, temperature control accuracy +/- 1.0 ℃, equipped with double-decked tempered Glass observation window for real-time monitoring of sample status.
Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1.0 ℃, using hot air circulation system to improve Temperature Uniformity, can adjust the air inlet and exhaust from the panel, with over temperature deviation protection and independent temperature limit alarm function.
Volume 50L, Temperature range RT + 10~ 300 ℃, hot air circulation system to improve Temperature Uniformity, with over-temperature protection and timing function, mirror stainless steel liner easy to clean, optional data recording and alarm system.
With independent temperature limit alarm system to ensure safe operation, Temperature resolution of 0.1 ℃, hot air circulation system to improve Temperature Uniformity, can adjust the air intake and exhaust from the panel, support optional data recording and communication functions.
High Accuracy Platinum Resistance Sensor for +/- 0.5 ℃ Temperature Fluctuation, Forced Circulation Convection Channel and 9999 Minute Timing, Double-decked Tempered Glass Viewing Window for Safe and Clear Sample Viewing.
Using digital microcomputer temperature controller accuracy of 0.1 ℃, equipped with double-decked tempered Glass observation window and hot air circulation system, to ensure that the indoor Temperature Uniformity +/- 2.0 ℃, with timing function and independent temperature limit alarm system.
Temperature range RT + 20~ 400 ℃ and Fluctuation only +/- 1 ℃, equipped with hot air circulation system to ensure Temperature uniformity, support 1~ 9999 minutes timing function, optional independent temperature limit alarm and RS485 interface to enhance security and data recording.
The fan speed control is used to improve the temperature uniformity, the air duct circulation system automatically discharges water vapor, the temperature control accuracy is +/- 1 ℃, and the mirror stainless steel liner is easy to clean.