Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, at 200 degrees high temperature can directly start the Compressor refrigeration, equipped with multiple Safety protection functions such as low water level anti-dry burning.
Equipped with powerful pressure suction pump to support peripheral groove thermostatic, Temperature Fluctuation is only +/- 0.1 ℃, pump flow 4L/min, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure sample safety.
The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C. At a high temperature of 200 ° C, the Compressor can be directly started for refrigeration without damaging the core components of the equipment.
The fluorine-free refrigeration system can be directly started at a high temperature of 200 ° C, with a Temperature Uniformity of +/- 0.05 ° C. It is equipped with a heat-free centrifugal pump to avoid its own heat generation affecting the temperature field, and supports multi-stage program temperature control.
Temperature range -40~ 200 ℃, Temperature Uniformity +/- 0.05 ℃, using non-heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, with multiple Safety protection including low water level anti-dry burning and Compressor overheating protection.
Adopt non-heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, support 200 ℃ high temperature direct start cooling without damaging the Compressor, with multiple Safety protection functions.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C, supports direct start of refrigeration at a high temperature of 200 degrees without damaging the Compressor, and is equipped with multiple Safety protection functions.
The use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, at 200 ℃ high temperature can directly start the Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices to ensure stable operation.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃. With 200 ℃ high temperature direct start refrigeration function, equipped with multiple Safety protection system to ensure stable operation of equipment.
The use of non-heat centrifugal circulation pump to avoid its own heat effect temperature field, Temperature Uniformity of +/- 0.05 ℃, at 200 degrees high temperature can directly start the Compressor refrigeration, to ensure the stable operation of the equipment.
The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway alarm, and supports 13L/min external circulation Flow rate.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C, supports 200 ° C high temperature to directly start Compressor refrigeration without damaging equipment, and is equipped with multiple Safety protection functions.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.
Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.