Constant Temperature Freezing Low Temperature Circulation Bath

The constant temperature freezing low-temperature circulation bath uses a compressor for refrigeration and a heater for temperature control, allowing the liquid inside the bath to circulate within a set low-temperature range. It is used in scenarios that require a stable low-temperature environment, such as laboratory sample cooling, reactor temperature control, and material testing.
Selection
When selecting, consider that the temperature range covers experimental needs, the temperature control accuracy meets sample requirements, the tank capacity fits container dimensions, confirm the compatibility of the heat transfer medium, and check safety protection features such as liquid level alarms and overtemperature protection.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

Temperature range -20~ 100 ℃, Temperature Fluctuation as low as +/- 0.05 ℃, support internal and external circulation, equipped with 6L/min circulating pump, to meet the precise temperature control of various experiments inside and outside the tank.

$ 830.00

Temperature range -5~ 99.9 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with internal and external circulation system, pump Flow rate 6L/min, suitable for experimental environment requiring precise temperature control.

$ 574.00

Temperature range -5~ 100 ℃, Temperature Fluctuation Accurate to +/- 0.05 ℃, equipped with circulating pump to support internal and external dual circulation mode, can flexibly meet the temperature control needs of in-tank and out-of-tank experiments.

$ 774.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Temperature range -30~ 99.99 ℃, Temperature Fluctuation +/- 0.05 ℃, support internal and external circulation system, pump Flow rate 6L/min, suitable for temperature sensitive experimental environment.

$ 877.00

Provide -15~ 99.9 ℃ wide range of temperature control, Temperature Fluctuation +/- 0.2 ℃, support internal and external circulation system, pump Flow rate 6L/min, suitable for a variety of testing environment needs.

$ 683.00

Using non-fluorine environmental protection Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor. The domestic circulation system avoids the heat generation of the water pump from affecting the temperature field, supports multi-capacity optional, Safety protection functions are complete.

$ 1264.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

The centrifugal circulation pump without heat is adopted to reduce the influence of temperature field, and the U-type reflux circulation realizes Temperature Uniformity +/- 0.05 ℃. It has safety devices such as power-off protection and low water level alarm, and can choose multi-stage temperature control program.

$ 1222.00

Temperature range -10~ 99.9 ℃, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, Tank volume 5/6L, support internal and external circulation, Pump Flow rate 6L/min, provide stable low temperature environment.

$ 659.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

With heating and cooling function, Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, Pump Flow rate 12L/min, Support internal and external circulation and remote communication, corrosion resistant design.

$ 974.00

Using microcomputer temperature control self-tuning PID adjustment technology, temperature control accuracy +/- 0.05 ℃, Temperature Fluctuation is small; fully enclosed Compressor refrigeration system, high refrigeration efficiency, low noise; professional circulation mixing design, pump Flow rate 10L/min, to ensure that the liquid in the Tank is evenly distributed and smooth.

$ 2825.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.