Temperature range -40~ 60 ℃, mirror stainless steel liner and fully enclosed imported Compressor ensure stable operation, suitable for a variety of scientific research scenarios.
With refrigeration and heating two-way temperature regulation function, Temperature range 5~ 50 ℃, volume 250L, suitable for thermostatic fostering and tissue cell preservation, support scientific research needs.
Equipped with 6.30 million pixel SONY IMX178 Sensor, it supports 3072x2048 resolution and 36fps dynamic image acquisition, with fast preview and compatibility with various third-party software functions.
Using a wire-wound process, the wet film thickness is 27.4 μm, with a coating width of 300 mm and a total length of 400 mm. The stainless steel material ensures durability and precise coating results.
Automatic measurement and display of dynamic and static Coefficient of Friction, Measurement accuracy +/- 1%, slider traverse speed 100mm/min, stable performance, accurate testing, complete functions, easy to operate.
Based on the national standard design, the static Coefficient of Friction and the dynamic Coefficient of Friction can be measured simultaneously, with a test accuracy of up to 0.001N, equipped with High Accuracy Sensor and special drive system to ensure smooth operation and accurate results.
Can simultaneously detect dynamic and static Coefficient of Friction, force range 0~ 5N, accuracy level 1, support microcomputer control and micro printer output test report.
Adopt imported accessories to ensure Stability, Blade Coating accuracy up to +/- 0.003mm, coating speed 5~ 200mm/s adjustable, effective coating area 400 * 400mm, improve film repRoducibility by controlling speed and pressure.
Using fluorine-free R134a refrigerant to achieve energy saving and environmental protection, Temperature Fluctuation +/- 1%, equipped with mirror stainless steel liner and adjustable shelf, support BOD detection and lighting observation, suitable for a variety of scientific research experimental environment.
High Accuracy Imported Sensor, Measurement accuracy up to 0.001N, test stroke 0-320mm adjustable, speed range 1-1200mm/min, support arbitrary slider mass setting, real-time display of force value Linear dispersion, automatic calculation of static and dynamic Coefficient of Friction.
Coating speed 5~ 180mm/s adjustable, meyer Rod coating accuracy of +/- 0.001mm, with Vacuum chuck and heating function, Temperature Uniformity +/- 3 ℃, support a variety of customized configurations.
It can automatically measure the dynamic and static Coefficient of Friction at the same time, using high-precision ball screw drive, the total error of the force measurement system is less than +/- 2%, and the micro printer can print multiple sets of results and the average value.
Using microcomputer control to achieve automatic testing, equipped with High Accuracy force sensor accuracy of 0.001N, special drive system running smoothly, can simultaneously measure static friction and dynamic Coefficient of Friction.
Manufactured using the wire-wound process, with a wet film thickness of 36.6μm and a coating width of 300mm, the stainless steel material ensures durability and precise coating results, meeting various experimental needs.
The device can measure 0~ 1 range of Coefficient of Friction, test force accuracy of +/- 0.001N, support stepless speed regulation to 550mm/min, suitable for a variety of standard tests, easy to operate, accurate and reliable data.