U-shaped tube design, viscosity measurement range of 0.9~ 3cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, suitable for a variety of liquid sample determination.
U-tube countercurrent design, viscosity measurement range of 200-1000cSt, accurate measurement based on the principle of liquid flow time in capillary tubing is proportional to viscosity.
U-shaped tube design, viscosity measurement range of 200-1000cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids at constant temperature.
U-shaped tube design, viscosity measurement range of 2000 to 10000cSt, based on the principle of liquid flow time in capillary tubing is proportional to kinematic viscosity to ensure accurate measurement.
U-tube countercurrent design, Measurement range 20-100cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity to ensure measurement accuracy and Repeatability.
U-tube countercurrent design, viscosity measurement range 0.6-3 cSt, accurate determination of liquid kinematic viscosity based on capillary tubing principle, suitable for a variety of liquid samples.
U-shaped tube design, viscosity measurement range of 60-300cSt, based on the principle of capillary tubing to achieve accurate measurement of liquid kinematic viscosity and outflow time.
U-shaped tube design, viscosity measurement range of 6-30cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, suitable for accurate measurement of various liquid samples.
Using U-Tube Reverse Flow BS/IP/RF design, the viscosity measurement range is 60000-300000cSt, which is based on the principle that the flow time of the liquid in capillary tubing is proportional to the viscosity to ensure accurate measurement.
U-tube countercurrent design, viscosity measurement range 6000-30000cSt, based on the principle of capillary tubing by measuring the liquid outflow time to accurately calculate the kinematic viscosity, suitable for high viscosity liquid analysis.
U-tube countercurrent design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing by measuring the liquid outflow time accurate calculation of kinematic viscosity, suitable for a variety of liquid samples.
U-shaped tube design, viscosity measurement range of 2-10cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, accurate viscosity measurement can be achieved.
Using U-tube vibration principle, only 2-3ml sample can be measured, density Precision +/- 0.0005g/cm ³, built-in Peltier temperature control device, support a variety of communication interfaces and user management functions.
U-tube countercurrent design, viscosity measurement range of 2000 to 10000cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, to ensure accurate measurement.
Using U-tube vibration principle, only 2-3ml sample, measurement Precision up to +/- 0.0003g/cm ³, built-in high definition camera video observation and up to 20 Measurement modes, support four levels of user rights management.