Gas-Liquid Emulsifier

The gas-liquid emulsifier mixes gas and liquid through high-speed shearing, forming tiny bubbles dispersed in the liquid. It is used in wastewater treatment, chemical reactions, and food processing to enhance gas-liquid contact efficiency, promoting mass transfer and reaction processes.
Selection
When selecting a gas-liquid emulsifier, consider the properties of the processing medium, the required bubble size, and energy consumption. Match the equipment's power with the processing capacity, check the material's corrosion resistance, ensure a simple structure for easy maintenance, and determine operating parameters based on the application scenario.

Terms

Instruments

The principle of thermal radiation is used to keep the liquid phase temperature below the boiling point, avoid boiling water droplets, and complete gas-liquid separation; the double condensation cycle design improves the extraction efficiency of pure water, the output of pure water reaches 400-500ml/hour, and the Heating power is 800-1000W to ensure that no heavy metals are detected.

$ 432.00

Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.

$ 143.00

The principle of thermal radiation is used to keep the liquid phase temperature below the boiling point, avoid boiling water droplets, and achieve complete gas-liquid separation; the output of pure water is 800-1000ml/hour, and the Heating power is 1500-2000W to ensure that no heavy metals are detected.

$ 548.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.

$ 154.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.

$ 875.00

Using 8-bit micro control technology, Response Time is less than 60 seconds, equipped with 12864 point array LCD display gas concentration, with sound, light and vibration triple Alarm mode, Protection Rating up to IP65.

$ 235.00

Using 32-bit microprocessor and 24-bit ADC chip, support 1-6 Sensor expansion, with 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for gas monitoring in harsh environments.

$ 451.00

Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.

$ 372.00

The imported movement motor has strong Power, the exhaust capacity is 456L/min to meet the high efficiency demand, the noise is only 53dB, and the operation is quiet. The gas storage Tank is treated with anti-rust and anti-bacterial treatment to ensure that the gas is clean.

$ 1689.00

Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.

$ 525.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00