Chemical line Rod

The chemical wire rod is a coating tool, consisting of a stainless steel rod wound with steel wire. It controls the wet film thickness through the gap between the rod and the substrate. It is used for the uniform coating of paints and inks in the laboratory, forming a standard-thickness coating to test properties such as hiding power and leveling.
Selection
When selecting, consider the wire diameter specifications corresponding to the coating thickness, choose corrosion-resistant stainless steel for the material, ensure the rod length matches the substrate width, note that the uniformity of wire winding affects the coating effect, and determine the appropriate wire diameter range based on the sample viscosity.

Terms

Instruments

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure Spreader uniformity and test accuracy.

$ 391.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure accurate and reliable test results.

$ 635.00

Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.

$ 244.00

Using film lamination technology, with 0.29mm paper Film thickness and surface Laminating, providing uniform film Spreader and solvent chemical resistance, easy hiding power, Opacity test.

$ 618.00

Adapted diaMeter 16mm formed Metering Rod, the total length of 2000mm, through the special structure to correct the straightness of the Rod body, to ensure stable rotation and full contact with the substrate, improve the thickness control accuracy of Spreader.

$ 590.00

Using film lamination technology, it has excellent solvent and chemical resistance, ensuring uniform film Spreader, paper Film thickness 0.29mm, surface Laminating enhanced durability, suitable for a variety of test environments.

$ 443.00

Using 100LPI line number and quadrilateral pyramid hole structure, the transfer uniformity of inks is precisely regulated through hole shape and line number, which affects the wet film thickness and ensures the stability of ink supply.

$ 167.00

Wet film thickness 22.9 microns, diaMeter 9.52 mm, the forming Rod uses an extrusion process to process continuous grooves, with no wire breakage and easy cleaning; the wire-wound Rod is based on the traditional principle, and there are differences in coating amount.

$ 167.00

Using film lamination treatment, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and surface Laminating to ensure Spreader uniformity and test accuracy.

$ 635.00

Using wire-wound stainless steel main Rod structure, wet film thickness 91.4 μ m, application width 300mm, through the formed process to achieve accurate Spreader, easy to operate.

$ 160.00

Adopting the formed preparation 1.5μm wet-film, stainless steel material is durable and easy to clean, suitable for a variety of Coating and chemical fields, application width 60mm.

$ 120.00

Rotation speed up to 28000rpm, line speed up to 27m/s, can handle materials with viscosity up to 8000cp, Modular structure supports a variety of head replacement to meet different experimental needs.

$ 751.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent, ensure Spreader uniformity and with annotation section for easy recording.

$ 509.00

Using stopwatch counting method, the length of the swing Rod is 500 +/- 1mm, and the total mass of the swing is 120 +/- 1g. The resistance to deformation is evaluated by measuring the ratio of the swing amplitude time on the film to the swing time on the Glass.

$ 251.00

Measurement range 0~ 1500μm, accuracy +/- (5μm + 5%), stylus end angle of 60 degrees, suitable for surface profile measurement, with line design for easy connection.

$ 774.00

Articles

The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Actual Coating Thickness Deviation of Stainless Steel Wire Rod Coaters at Different Slurry Solid Contents
This article analyzes the actual coating thickness deviation of stainless steel wire rod coaters under different slurry solid contents. The study finds that the solid content of the slurry affects its viscosity and flowability, leading to deviations in the actual coating thickness from the theoretical value.
Coating film preparation techniques: comparison between wire-wound applicators and wet film preparators
This article compares two commonly used tools in laboratory coating film preparation: the wire rod coater and the wet film applicator.
The laboratory coating machine easily coats various aqueous and oily slurries.
The laboratory film applicator is a precision instrument used to prepare uniform coatings on substrates, primarily operating on the principle of a blade or wire-wound rod. It allows adjustment of parameters such as speed and pressure to control coating thickness.
How to achieve high uniformity in silver nanowire transparent conductive films through wire rod coating
This article introduces how to prepare uniform silver nanowire transparent conductive films using the wire rod coating technique. These films, which use silver nanowires as the conductive material, exhibit high transparency and conductivity, making them suitable for applications such as touch panels.
Common Troubleshooting for Wire Bar Coater: Solving Issues of Streaking and Uneven Thickness
This article mainly introduces solutions to two common faults in the operation of the wire rod coater—coating streaks and uneven coating thickness.
Blade Coating VS Wire Rod Coating: The Precision Battle and Selection Guide in the Lab
Blade coating and wire bar coating are two commonly used physical coating methods in laboratories. When selecting between them, factors such as material properties, target thickness, and experimental conditions must be considered. Both methods have their own advantages and can be flexibly chosen or used to validate each other based on specific requirements.
Application of Wire Bar Coater in the Preparation of Coating, Ink, and Printing Samples
A wire-wound rod coater is a laboratory tool used for preparing uniform wet film coatings on flat substrates, widely applied in the production of samples in the coatings, inks, and printing industries.
The working principle of laboratory wire rod coaters and methods for controlling coating thickness
The laboratory wire rod coater is a precision instrument used to prepare uniform, thickness-controllable wet film coatings on substrate surfaces. Its core components include a coating rod, a flat coating platform, clamps for securing the substrate, and a mechanical system that drives the coating rod to move at a constant speed.
Inventory of Laboratory Coating Instruments
Laboratory coating tools include gap coaters, wire rods, automatic coating machines, etc. What are the differences between them? This article will tell you!
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
The difference between a wire-wound rod coater and an extrusion coating rod
This article primarily compares the technical differences between wire-wound and extrusion coating rods. Although they are interchangeable in most scenarios, there are subtle variations in liquid loading capacity due to their distinct groove principles.
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.