The high and low temperature constant temperature water bath maintains the liquid in the tank at a constant set temperature range through a heating and cooling system and a circulation pump. It is used for experiments such as constant temperature reactions of samples, viscosity testing, and material aging, providing a stable temperature environment for paint curing and ink drying tests.
Selection
When selecting, consider that the temperature range covers experimental requirements, temperature control accuracy meets testing standards, tank capacity accommodates sample dimensions, and circulation flow ensures temperature uniformity. Pay attention to the cooling power for low-temperature conditions, corrosion-resistant materials for chemical environments, and an operating interface that aligns with usage habits.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

High Accuracy Sensor and integrated components to achieve temperature control, temperature resolution 1 ℃, stainless steel liner corrosion resistance, Tank volume 20L, suitable for thermostatic experiments.

$ 275.00

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, with over-temperature water cut-off alarm function, built-in circulating water pump can output thermostatic water flow.

$ 622.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing and over-temperature water cut-off alarm, to ensure the stability and safety of the experiment.

$ 285.00

Adopt stainless steel liner and microcomputer intelligent temperature control instrument, with 0.1 ℃ temperature resolution and +/- 0.5 ℃ Fluctuation, support timing and over-temperature water cut-off alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.

$ 188.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.