Paint Color Matching Cabinet

The paint color matching cabinet eliminates interference from lighting variations on color judgment by simulating standard light source environments. It is internally equipped with multiple light sources, such as D65 daylight and TL84 store light. During operation, samples and standard color swatches are placed side by side for observation. It is used for color comparison in paint production and quality inspection processes to ensure color consistency across batches.
Selection
When selecting, pay attention to the light source type to ensure it matches industry standards. The cabinet size should accommodate common samples. The interior walls should be neutral gray to avoid glare interference. Check the lifespan and replacement method of the light source. Consider the cabinet's sealing and ease of operation, and confirm compliance with basic specifications such as ASTM D1729.

Terms

Standards

Instruments

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

With illumination adjustment function, support D65 Illuminant to meet CIE Class A Light spectrum matching, no need to warm up and no flicker, equipped with 45 degree observation station to achieve 45/0 observation conditions, suitable for large items Colorimetric.

$ 4237.00

With three light sources including D65, TL84 and D50, high color strength index CRI = 98, the all-metal material is stable in structure, providing uniform lighting and accurate color evaluation, suitable for a variety of industry environments.

$ 1961.00

Standard light sources covering 6500K to 2700K Color temperature range, support UV detection; no need to warm up and open immediately, low energy consumption without heating; Illuminant use time can be displayed, with 45 ° standard stand optional.

$ 315.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

With four Illuminant automatic switching function, display the use time of each Illuminant, no need to warm up without flashing, Color temperature range covers 2700K to 6500K, low energy consumption without heating, support Metamerism detection.

$ 354.00

Using high color rendering index CRI = 98 D65 light source, equipped with 4 36W lamps and light source Timer, all-metal structure to ensure stable and uniform light, in line with ISO3664 international standards.

$ 1735.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.