Electromagnetic Viscosity Meter

The electromagnetic viscometer operates on the principle of electromagnetic induction, causing a metal rotor to rotate within the sample and measuring the electromagnetic force exerted on the rotor to calculate viscosity. It is used for detecting the viscosity of fluids such as coatings and inks, and is suitable for rapid measurements in production environments.
Selection
When selecting, consider that the measurement range covers the sample viscosity, the accuracy meets the process requirements, the rotor material is resistant to sample corrosion, the temperature adaptability matches the operating environment, and the portability of the equipment and sample volume are suitable for the actual usage scenario.

Terms

Standards

Instruments

Using electromagnetic force equilibrating Sensor, accuracy of 1mg, Stabilization time ≤ 6s, with RS232 Communication interface, counting function and density measurement and other practical functions.

$ 412.00

High Accuracy Electromagnetic Force Sensor, dynamic temperature compensation technology to ensure accuracy, repeatability error +/- 2mg, standard RS232 interface can transfer data directly to Excel.

$ 456.00

High Accuracy Electromagnetic Force Sensor, Capacity 520g, readability accuracy 0.1mg, OLED display and Draft Shield static elimination design, support external calibrating and multiple unit switching.

$ 2765.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 1mg, Draft Shield static elimination design, support for external calibrating and multiple weighing units for special application needs.

$ 1816.00

High Accuracy Electromagnetic Force Sensor, Capacity 320g, readability 0.1mg, support automatic internal calibrating and multiple weighing units, equipped with transportation protection devices.

$ 1230.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 0.2mg, dynamic temperature compensation technology to ensure weighing accuracy, reaction time is less than 3 seconds, support a variety of unit weighing.

$ 498.00

High Accuracy Electromagnetic Force Sensor, Capacity 320g, readability 1mg, support for external calibrating and multiple weighing units, equipped with transportation protection devices to ensure safety.

$ 708.00

Electromagnetic Force Sensor, repeatability error +/- 3mg, linear error +/- 3mg, with dynamic temperature compensation and external calibrating function, reaction time is less than 3 seconds, support a variety of weighing units.

$ 1037.00

Adopting a stepper motor automatic positioning and electromagnetic release system, the swing period is 1.4 seconds, and the steel ball diaMeter is 5 mm, providing visual and acoustic test end signals.

$ 1058.00

High Accuracy Electromagnetic Force Sensor with readability up to 0.01mg, support for automatic internal calibrating and multiple weighing units, Draft Shield static elimination design guarantees accuracy.

$ 3346.00

High Accuracy Electromagnetic Force Sensor, Capacity 520g, readability accuracy 1mg, support auto calibration and multiple weighing units, Draft Shield eliminates static electricity design to ensure weighing accuracy.

$ 945.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 1mg, OLED backlit display to support glove operation, Draft Shield to eliminate static electricity and lower hook design to meet special application needs.

$ 751.00

Adopt a new generation of electromagnetic force Sensor to ensure stable and reliable weighing, readability accuracy of 0.1mg, equipped with ultra-clear OLED backlight display and Draft Shield static elimination design, support a variety of weighing units and lower hook applications.

$ 1313.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 2mg, equipped with dynamic temperature compensation technology to ensure weighing stability time is less than 3 seconds, support a variety of weighing units and lower hook design.

$ 591.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 0.1mg, Capacity 220g, Draft Shield to eliminate static electricity and lower hook design, support multiple units and data interfaces, built-in dual system to ensure reliability.

$ 925.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.