Halogen Analyzer

Halogen analyzers detect the content of chlorine, bromine, fluorine, and iodine by generating gases through sample combustion and employing microcoulometry or ion chromatography. They are used to detect restricted halogen substances in plastics and electronic materials, ensuring compliance with environmental regulations.
Selection
When making a selection, consider that the detection limit must meet regulatory requirements, the sample type must match the injection system, the detection range for chlorine, bromine, fluorine, and iodine must cover the needs, and the ease of instrument maintenance and operating costs should align with laboratory conditions.

Terms

Standards

Instruments

Using an annular halogen lamp to heat uniformly, the sample is rapidly dried in just a few minutes, the moisture measurement range is 0.00 to 100%, and 9 paraMeters including water loss rate and temperature can be displayed.

$ 344.00

Ring halogen lamp heating, 0.02% moisture readability, RT +~ 180 ℃ Temperature range, automatic measurement, Draft Shield design, pure stainless steel heating Chamber cover, 16 sets of Data storage.

$ 503.00

Using annular halogen lamp heating, heating fast and uniform, Heating Temperature range RT + 40~ 199 ℃, moisture accuracy of 0.1%, with imported Sensor to ensure stable weighing, support data storage and printing.

$ 814.00

Ring halogen lamp heating to ensure that the sample uniform rapid drying, Capacity 20g, Temperature range RT +~ 160 ℃, high detection efficiency and sample surface is not easily damaged.

$ 344.00

The annular halogen lamp is used to heat the sample evenly and quickly, and the surface is not easily damaged. Capacity 100g, moisture measurement range 0.00~ 100%, and the general sample can be measured in a few minutes.

$ 388.00

Using annular halogen lamp heating, the sample is uniform and fast drying, the surface is not easy to damage, Capacity 100g, Heating Temperature range RT +~ 160 ℃, the general sample can be measured in a few minutes.

$ 319.00

Using annular halogen lamp heating, Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement; Equipped with Draft Shield and imported Sensor, the heating performance is uniform and stable, supporting the simultaneous conversion of water content and solid content.

$ 441.00

Using halogen lamp heating technology, Capacity 110g, readability 0.001g, heating temperature up to 200 ° C, fast drying and real-time display of moisture percentage, suitable for a variety of sample analysis.

$ 566.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Ring halogen lamp heating to ensure uniform and fast drying of samples, Capacity 50g, Measurement accuracy 0.01%, support 0~ 99 minutes timing, 9 kinds of paraMeter display, suitable for solid, particle and other Sample types.

$ 344.00

Using halogen lamp heating technology, Capacity 110g, temperature adjustment accuracy +/- 1 ℃, rapid drying of samples and real-time display of moisture percentage, suitable for a variety of sample detection.

$ 483.00

The annular halogen lamp is uniformly heated, Capacity 50g, moisture measurement range 0.00-100%, heating temperature can reach 160 ℃, the general sample can be measured in just a few minutes, and the detection efficiency is high.

$ 388.00

Using halogen lamp heating, the fastest few minutes to complete the measurement, Capacity 110g, heating temperature up to 199 ℃, consistent with the international Oven method results, higher efficiency, can store 15 sets of data and connect to a computer printer.

$ 788.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

The annular halogen lamp uniformly heats the sample, Capacity 50g, Moisture measurement range is 0.00~ 100%, and the measurement is completed within a few minutes. The results are consistent with the Oven method and the efficiency is higher.

$ 319.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.